Warning

Keep the unit always in an

upright position.

Inclining the unit may cause water

in the tank to leak into the unit,

resulting in malfunction

. Should

you incline the unit accidentally,
contact the place of purchase for
advice.

Do not carry the unit horizontally.

This may 

result in malfunctions

.

Do not point air-flow from
the unit directly at the
body .

If air-flow is directed at the body for
long periods, it may 

harm one’s

physical condition

and 

lead to

dehydration

.

Install the unit in a location where
the floor is flat and stable.

If the unit falls over, the water
collected in the water tank may
leak damaging surrounding objects
and in turn result in 

fire or electric

shock caused by an electrical
leak

.

Grasp the plug and remove
from the power socket.

When removing the plug from the
power socket, do not pull on it
diagonally or by the cord as this
may cause the projections/wiring to
be damaged resulting in 

a short

circuit, electric shock or fire

.

Before moving the unit always
switch it off, unplug it and remove
water from the water tank.

Moving the unit with water in its
tank may cause the water to leak
and damage the surrounding
objects and in turn result in 

electric

shock and/or an electric leak

.

After emptying the tank,
transport the unit by grasping
the handle firmly.

Losing your footing while carrying
the unit may cause personal injury
or damage to the floor.

When using the continuous
drainage outlet, make sure
to position the hose so that
the water drains without
obstruction.

The water in the tank may leak and
damage 

surrounding objects

.

When draining water
continuously or left
unattended for long
periods, inspect the unit
every two weeks.

Do not allow debris to clog
the filter/hose as this may
cause over-heating/leakage.

Use the unit with caution in
rooms where the walls,
furniture and art work is
vulnerable to dry air, as it
may cause cracks and warping.

Switch the unit off and
unplug from the power
source when cleaning it.

When the unit is on, the internal fan
rotates at high speeds and may

cause injury

.

Unplug the unit from the
power source when not
using the unit for an
extended period of time.

Otherwise it may cause 

fire and/or

electric shock caused by an
electric leak

.

CAUTION

The appliance is not inteded for use by young children or infirm persons without supprvision;

Young children should be suppervised to ensure that they do not play with the appliance

Summary of Contents for MJ-E26SX-A1

Page 1: ...d the swing monitor Information display 13 High humidity warning Defrosting indicator Low temperature indicator Negative ion lamp Tank full lamp Using the Timer 14 OFF Timer operation ON Timer operation Using the Child lock 16 Carrying the unit 16 Removing water from the tank 17 Continuous drainage 18 Maintenance 19 Replacing the Air purifying filter 21 Storage 21 Troubleshooting 22 Specifications...

Page 2: ...vents leaving depressions on carpets Drain the water tank before use Refrain from opening doors windows during operation Objective Recommended mode and louvre setting Page Drying laundry When you don t want to hang the clothes outside or it is raining Selection Laundry Swing Louvre Up Selection Mode Swing Louvre page10 page10 11 page12 Selection Easy Dehumidifying Mode Auto Mode Low Temp Mode Mild...

Page 3: ... fire Wipe dust off the power plug and insert the plug firmly If the plug is not fully inserted into the socket dust may gather on the connectors which may cause fire and or electric shock Use 220 240V AC power sockets that can withstand more than 15A current Connecting to power sockets other than 220 240V AC may result in fire and or electric shock Remove water that has collected in the tank Acci...

Page 4: ... use the unit in places where chemicals are used such as hospitals factories laboratories or beauty salons Chemicals and solvents evaporated in the air may harm the unit and cause water in the tank to leak resulting in damage to property Do not use the unit for special purposes such as preservation of food art or scientific works This may negatively affect the quality of the items stored Do not dr...

Page 5: ...nk may cause the water to leak and damage the surrounding objects and in turn result in electric shock and or an electric leak After emptying the tank transport the unit by grasping the handle firmly Losing your footing while carrying the unit may cause personal injury or damage to the floor When using the continuous drainage outlet make sure to position the hose so that the water drains without o...

Page 6: ... not cover Main Air Outlet Tank Lid Control Panel Tank Guard Float Level Window The water tank may contain water residue at time of purchase This is from final product testing at the factory and is not due to a defect 12 16 Lamp Current mode lights Selection button Switches modes 7 operating mo SELECTION EASY DEHUMIDIFYING LAUNDRY 10 9 17 9 17 17 16 18 Low Air Outlet Water Tank 9 17 19 19 Wheel 4 ...

Page 7: ...ower is OFF and the humidity rises Lights when the defrosting function is operating Lights when the power is ON and the room temperature drops below 15 C All indicators on the LCD panel shown below Timer ON OFF Sets timer Tank full lamp This lights up to warn that the water tank is full Mode Indicator Indicates the current operating mode Humidity Indicator This indicates the approximate humidity i...

Page 8: ... particles in the air that possess a negative charge When there are a lot of negative ions in the air it is similar to the environment encountered in a forest and is said to provide relaxation Re heating coil Cooling coil Moist air Compressor Dried warm air Water tank The dehumidifier does not have a cooler function Due to heat produced during operation the room temperature may rise 2 4 C As a res...

Page 9: ...perate the dehumidifier when the room temperature is above 40 C If the temperature is below 1 C the extracted water is close to freezing disabling the dehumidifier and only the blower is operational Air purifying function While the air purifying filter is installed and the unit is running the air purifying function operates all the time Before using your dehumidifier Turning the Unit ON and OFF In...

Page 10: ... You can choose between seven operating modes Information Information Pressing HUMIDITY SELECTION while in Easy Dehumidifying or LAUNDRY modes changes the mode to AUTO Reading the humidity display Easy Dehumidifying Laundry modes High Low Mildew Guard Low Temp and Auto modes SELECTION indicates set humidity level Automatic mode only Even if Automatic mode is not selected using MODE it can be activ...

Page 11: ...y level with the indicator After 3 seconds the display returns to the current humidity display Pressing HUMIDITY SELECTION while is displayed sets the humidity level Each time the button is pressed the humidity setting changes Mildew Guard The unit lowers room humidity levels once a day for approximately 2 4 hours suppressing mildew growth Once every 24 hours the dehumidifier runs for 2 hours if t...

Page 12: ...ed is automatically controlled to send air to all corners of the room Swings slowly to send air further Press With each press of the button Starts swing operation The swing monitor is displayed The swing operation stops when the power cord is unplugged Viewing the Swing Monitor This indicates the range of louvre swing The louvre and monitor do not move in synchronization Stop swing operation The l...

Page 13: ...unit beeps continuously Air flows stops louvre stops Monitor turns off Negative ion lamp turns off After removing the water and replacing the tank the Tank full lamp will go off and the unit will automatically return to operation mode When the Tank Full lamp is lit no operation but ON OFF is possible is displayed when the unit is melting the frost accumulated inside and draining it to the tank The...

Page 14: ...ours Set the timer when the power is switched on To set 1 Switch the power on 2 Select operating mode Select desired operating mode 3 Change the louvre swing direction Select the desired setting 4 Set the operating time When pressed once the figure and OFF appear Each subsequent press changes the display in order from 1 to 9 hours Hold the button to run automatically through the numbers The OFF ti...

Page 15: ...n Press once The Power lamp Mode indicator and a on the digital display flash The ON indicator lights Each subsequent press changes the display in order from 1 to 9 hours Hold the button to run automatically through the numbers 3 Select operating mode Select desired operating mode 4 Change the louvre swing direction Select the desired setting 5 Confirm the operating start time Power lamp and Time ...

Page 16: ... cord Using the Child Lock To Lock The child lock indicator The child lock is switched off when the power cord is unplugged When the child lock is activated the unit cannot be switched off or on The other switches are also inoperable until the child lock has been released Releasing the child lock The child lock lamp goes out Press for 3 or more seconds Press for 3 or more seconds If you lock the u...

Page 17: ...y the tank full light will come on and the unit will not operate Do not remove or dismantle the floating element in the tank If it is removed the unit cannot detect when the tank is full and this could result in leakage Tank Lid Empty water from here Removing Water from the Tank The unit automatically shuts down and lights the Tank full lamp when the tank approximately 5L is full Empty the tank 1 ...

Page 18: ...ons 4 Insert the hose into the drainage outlet on the back Feed the commercially available hose ID 15 mm into the drainage outlet while keeping the stopper pressed 5 Replace the tank The unit cannot operate without returning the tank CAUTION Do not drain water continuously if there is a possibility that temperatures around the hose could drop below freezing point Water inside the hose may freeze a...

Page 19: ...The air purifying filter cannot be washed in water Replace the air purifying filter when it becomes dirty 3 Clean the air filter Run a vacuum cleaner lightly over the air filter surface to remove the dirt Hose with lukewarm water when excessively soiled Dry well 4 Set the air purifying filter Set the air purifying filter into the air filter with the lattice side facing up 5 Attaching the air filte...

Page 20: ...he tank to gradually become dirty If the dirt does not come off easily wash with cold or warm water then wipe with a soft dry cloth Maintenance Do not use detergents cleaning agents for heat exchange equipment abrasive powders chemically treated dusters gasoline benzene thinners or other solvents as they can damage the unit or the water tank which may result in leakage Cleaning ...

Page 21: ...e conditions Replacing air purifying filter For maintenance procedures see p 1 Remove front panel and air filter 2 Replace air purifying filter 3 Attach air filter and front panel 1 Bundle power cord 2 Remove the drainage water 3 Clean air filter 4 Store the unit When you are sure that all parts of the unit are dry cover it with a cloth to keep it from dust Store the unit in an upright position in...

Page 22: ...Remove the obstruction Check to see if the air filter is clogged Clean according to the maintenance procedures Check to see if the unit is in FULL AUTO MILDEW GUARD or AUTO The unit is automatically controlling the dehumidifier fan and standby times Check to see if the water tank is full Empty the water tank and return it to its original position Check to see if the water tank is inserted properly...

Page 23: ...hanges modes or stops This is the sound of the compressor In modes that monitor the humidity level the compressor operates intermittently causing the sound to be heard occasionally The compressor does not activate after turning the unit off or for 3 minutes after plugging the unit into a power socket This is to protect the compressor from damage The heat converter heats rapidly causing an odour Th...

Page 24: ...pproximately 2W NOTE It is impossible to remove the back panel because the two spots shown are fastened with two special screws If the unit malfunctions contact your Mitsubishi dealer Fill in the following for your future reference Place of purchase Telephone number Date of purchase Day Month Year T939Z126H64 Distributed and guaranteed throughout New Zealand by Black Diamond Technologies Ltd Auckl...