background image

9

E

Bef

or

e Using the Unit

” is displayed when the room 

temperature drops below 15°C.

When “

” is shown, it is 

recommended that the HIGH 
dehumidification mode be activated.

15

 

z

FULL Lamp

Lights when the tank is full of water.

22

 

z

DRYING INSIDE 
Lamp

 

z

Flashes during the 
DRYING INSIDE 
operation.

 

z

Lights when the DRYING 
INSIDE operation is 
waiting to begin.

 

z

DRYING INSIDE 
Switch

Use this to switch the 
DRYING INSIDE operation 
ON and OFF.

19

 

z

POWER Lamp

Lights during operation.

 

z

POWER Switch

Turns the power ON/OFF.

12

Low 
Temperature 
Indicator

Information Display

Indicates the dehumidifier 
and room conditions.

High Humidity 
Warning

” flashes when the unit is OFF and the 

humidity in the room exceeds 75%.

” is flashing, activating the 

dehumidifier is recommended.

If the High Humidity warning is not used, 
remove the power plug from the power 
socket.

 

z

AIR PURIFIER Lamp

Lights during air purifier 
operation only.

 

z

AIR PURIFIER Switch

Switches to air purifier 
operation only.

17

You can select from 8 operating modes

 

 INTELLIGENT   

LAUNDRY

 

 NIGHT  LAUNDRY

 

 HIGH

 

 LOW

 

 MILDEW  GUARD

 

 EASY

 

 AUTO

 

 AIR  PURIFIER

All modes 
include 
dehumidifier 
and air purifier 
functions.

Air purifier 
operation only. 
The dehumidifier 
function is 
disabled.

Summary of Contents for MJ-E130AL-H

Page 1: ... of Mildew in Bathroom MILDEW GUARD 16 z Cleaning the Air AIR PURIFIER 17 z Using Child Lock 17 z Using Louvre 18 z Drying Inside Operation 19 z Using Timer 20 OFF TIMER ON TIMER z Draining 22 z Continuous Drainage 23 z Maintenance 24 z Replacement Parts 25 z Storage and Disposal 25 z Troubleshooting 26 z Specifications 28 DEHUMIDIFIER MODEL MJ E130AL H INSTRUCTION MANUAL Features z 2 Types of Lau...

Page 2: ...IGHT LAUNDRY z HIGH P 12 P 12 P 15 Tips on Drying Laundry P 13 When you want to perform automatic operation When you want to perform continuous operation When you want to set the humidity Reducing blowing sound and performing continuous operation z HIGH z AUTO z EASY z LOW P 14 P 15 P 15 P 15 When you want to dehumidify z MILDEW GUARD P 16 When you are worried about mildew in the bathroom z AIR PU...

Page 3: ...he moisture to transform into water droplets 2 The water droplets fall into the water tank 3 Dehumidified air is heated by the re heating coil and then blown out The humidity of the room is thus reduced by repeating the above steps z The amount of dehumidifying becomes less in winter When the temperature and humidity are low the amount of water collected is decreased In winter because the temperat...

Page 4: ... not put the unit near heat generating devices such as stoves fan heaters etc The plastic parts may melt and cause fire Do not put your fingers or any long object into the air intake outlet Do not touch the swing louvre The internal fan rotates at high speeds and such actions may result in injury Do not attempt to repair disassemble or modify the unit This may result in fire and or electric shock ...

Page 5: ... Do not use the unit for special purposes such as preservation of food art or scientific works This may negatively affect the quality of the items stored Do not point airflow from the unit directly at the body for a prolonged period of time Be especially careful when using the unit where there is someone who is unable to adjust the humidity infant child or elderly person If air flow is directed at ...

Page 6: ... remove from the power socket When removing the plug from the power socket do not pull on it diagonally or by the cord as this may cause the projections wiring to be damaged resulting in a short circuit electric shock or fire Switch the unit off and unplug from the power source when cleaning it When the unit is on the internal fan rotates at high speeds and may cause injury Unplug the unit from th...

Page 7: ... time of purchase Set it before use 10 What is the silver ion filter The silver ion filter has a two layer construction consisting of a white particle filter and a blue air freshener filter Particle filter The fine particle filter removes pollen and dust particles Diameter of pollen approx 10 100 μm Air freshener filter A special deodorant and anti bacterial agent antiallergen anti virus and sterilizatio...

Page 8: ...N Switch Sets the humidity 14 16 z SWING LOUVRE ON OFF Switch Sets swinging louvre direction or locks it into position 18 20 21 z ON OFF TIMER Switch Sets timer LCD Display z Operating Mode Indicator Indicates the selected operating mode 14 16 z Humidity Indicator Indicates the approximate humidity Current humidity Humidity setting in AUTO mode The humidity is displayed in a range from 30 to 80 3 ...

Page 9: ...ON OFF 12 Low Temperature Indicator Information Display Indicates the dehumidifier and room conditions High Humidity Warning flashes when the unit is OFF and the humidity in the room exceeds 75 is flashing activating the dehumidifier is recommended If the High Humidity warning is not used remove the power plug from the power socket z AIR PURIFIER Lamp Lights during air purifier operation only z AI...

Page 10: ...Insert the bottom tabs into the unit until they click Before Using Your Dehumidifier Setting the silver ion filter The silver ion filter is supplied with the unit at time of purchase Please install it before using the unit 1 Remove the silver ion filter from the polyethylene bag 2 Remove the pre filter Performance is unaffected even if the metal fin inside the unit are slightly bent Pull the pre f...

Page 11: ...ve this unit so as to prevent overturning z Do not carry the unit by holding the downward louvre Note z Do not put the unit in horizontal position during carrying as this may cause malfunctions z Use wheels to move the unit steadily in one direction z Lift the unit up to go over the doorsill or stairs and do not use wheels to move the unit over the shaggy carpet as this may damage the carpet z Do ...

Page 12: ...to approximately 12 hours r INTELLIGENT LAUNDRY It is recommended for shortening the laundry drying time r NIGHT LAUNDRY It is recommended for reducing the noise emitted from the unit The drying time is longer than that of INTELLIGENT LAUNDRY The unit stops dehumidifying when the water tank becomes full and the blower begins to operate Information z Remove the water from the tank before operating ...

Page 13: ...r z The laundry is of a large volume Shift the position of the laundry during drying so that each part can get the blowing air About the Room for Hanging Clothes z In a small room it is recommended that the door and window be closed before dehumidifying It is effective not only to dehumidify but also to dry the laundry as soon as possible z When the room temperature is low such as in winter Use a ...

Page 14: ...Blip 12 Blip z AUTO In order to maintain the humidity level the unit operates intermittently after automatic switching of air flow rate z When the current humidity is lower than the set value the unit will stop both the blower louvre will stop It will restart if the humidity level is higher than the set value z For 6 minutes after the power is on the unit will begin operating regardless of the room...

Page 15: ...ou want to dehumidify with lower blower sounds z EASY To relieve the discomfort from dampness the unit operates intermittently after the automatic switching of airflow rate Blowing air is used to control the room temperature rise if the room temperature is high It is recommended when you want to maintain the comfortable level of humidity z If the set humidity level is reached sometimes the blower l...

Page 16: ...change the swing direction 18 When choosing the swing settings except for Downward setting please adjust the orientation of the unit first z As this mode will have automatic air flow control it is impossible to set the airflow and use it with other operating modes or humidity setting When you want to abort the operation z To stop the operation mode halfway Press the POWER switch POWER OFF z To swi...

Page 17: ...is set only the CHILD LOCK switch can be used When the child lock is activated other switches are not operable Deactivate the child lock in order to use other switches z The child lock is cancelled when the power cord is unplugged Releasing the child lock Press for 3 seconds or more z The child lock indicator goes out Cleaning the Air 3 163 3 To operate the air purifier only 1 2 1 Press Blip 12 2 ...

Page 18: ...even distribution of air supply to the laundry To dehumidify carpets and beds To dry training shoes r Downward The louvre does not swing The angle of louvre can be adjusted manually for downward air blowing 3 section adjustable louvre The louvre is adjusted in the air blowing direction so do not close the louvre Adjust the louvre direction by hand To dehumidify closets r Rear The louvre swings to ...

Page 19: ...DRYING INSIDE switch when the POWER is ON The DRYING INSIDE lamp turns off Manual Operation The DRYING INSIDE operation can only start when the POWER is OFF Blip Press while the POWER is OFF z DRYING INSIDE operation starts The DRYING INSIDE lamp flashes the humidity indicator turns off and the louvre stops in the vertical position DRYING INSIDE Operation z DRYING INSIDE operation ends The DRYING ...

Page 20: ...ation 4FUUJOH 0 5 3 1 Switch the power ON 12 2 Select operation mode 12 17 Select the desired operation mode 3 Change the louvre swing direction 18 Select the desired louvre swing direction 4 Set the operation time z Press once to display z Each press will change the display in the sequence of 1 to 9 hours Holding the switch will cause the display to change continuously Blip Blip Blip No display c...

Page 21: ...ower OFF 12 2 Set the time you wish the unit to turn ON Blip Press z Press once the POWER lamp lights operating mode indicator and on the digital display flash and is displayed z Each press will change the display in the sequence of 1 to 9 hours Holding the switch will cause the display to change continuously Blip Blip Blip No display operation stops Blip Blip 3 Select operation mode 12 17 Select ...

Page 22: ...ndicator In NIGHT LAUNDRY mode z When the water tank becomes full the unit stops dehumidification but the air supply continues Though the FULL lamp lights there will be no warning sound The air supply continues even if the water tank has been removed 3 Slide the tank lid to close the tank 4 Check the tank and firmly push it all the way in Confirm that the tank lid and the tank guard are securely at...

Page 23: ...n water and then insert it Do not use oils or lubricants z Inspect the hose once every 2 weeks Insects or dirt deposits in the hose may cause leakage Note CAUTION Do not drain water continuously if there is a possibility that temperature around the hose could drop to freezing point Water inside the hose may freeze and prevent the water in the tank from flowing out The water may leak from the unit a...

Page 24: ...ter 10 When the pre filter is very dirty wash it with warm water or clean water and dry it well Use a vacuum cleaner to suck up dirt 0ODF WFSZ 5ISFF POUIT Silver ion filter Soak the silver ion filter in water How to remove and attach the filter 1 Remove the pre filter 2 Remove the silver ion filter 3 Soak the silver ion filter in water z There may be yellow or dark stains remain on the filter but ...

Page 25: ...s 10 After switching the unit POWER off leave for one day until any residual water inside is removed Then carry out the following steps 1 Perform the DRYING INSIDE operation DRYING INSIDE operation is recommended for prevention of mildew growth inside the unit 2 Hang the power cord on the cord hook 3 Drain out the water 22 Drain any water from the water tank and wipe off any remaining water 4 Clea...

Page 26: ...work as set z The residue is from final product testing at the factory and is not a malfunction The water tank contains liquid or white water residue z The residue is from the dirt in the air o Clean according to the Maintenance procedures 24 There is black residue on the inside of the water tank and lid z Check to see whether the power cord is off o Plug the power cord fully into the power socket ...

Page 27: ... from damage 12 The unit makes noises The operating noise is loud reverberates The operating sound suddenly increases in volume The air blowing sound changes in volume The unit produces a simmering sound The unit produces a buzz that sounds intermittently or the compressor does not activate When first used z The temperature of heat exchanger goes up rapidly causing transient odor z The discharged ...

Page 28: ...ng Ltd Head office Tel 2510 0555 Service Centre Tel 2427 8484 Model MJ E130AL H Power supply Single phase 220 V 50 Hz Condition Temperature 26 7 C 30 C Relative humidity 60 80 Dehumidifying capacity 1 13 0 L day 22 5 L day Power consumption 240 W 290 W Recommended room size 2 HIGH 3 54 m2 EASY 36 m2 Water tank capacity Stops automatically at approx 4 7 L Weight 14 4 kg Dimensions H W D 594 mm 372 m...

Reviews: