3 BASIC FUNCTION
3.12 Assigning I/O devices
119
3
Setting method [A]
Servo parameter list
Input/output device selection, input signal automatic ON selection, input signal filter selection, and DI pin polarity selection
settings can be performed directly with servo parameters.
*1 Available on servo amplifiers with firmware version A5 or later.
Servo
parameter
Symbol
Name
Outline
PD01.0-3
*DIA1
Input signal automatic ON
selection 1
The input devices to which "Automatic ON" is set, can be selected.
For the initial value, refer to each servo parameter.
PD03 to PD14,
PD17 to PD22,
PD43 to PD46
Any input device can be assigned to the specified pin of the CN3.
For the initial value, refer to each servo parameter.
PD23 to PD26,
PD28, PD47
Any output device can be assigned to the specified pin of the CN3.
For the initial value, refer to each servo parameter.
PD29.0
*DIF
Input signal filter selection
The input signal filter can be selected.
Initial value: 7h (3.500 [ms])
PD29.1
*DIF
RES signal dedicated filter
selection
The RES (Reset) dedicated filter can be selected.
Initial value: 0h (disabled)
PD29.2
*DIF
CR signal dedicated filter
selection
The CR (Clear) dedicated filter can be selected.
Initial value: 0h (disabled)
PD60.0-2
*DIP
DI pin polarity selection
The polarity of the DI pins can be selected.
Initial value: 000h (ON with 24 V input)