4 STARTUP
4.3 Switch setting and display of the servo amplifier
43
4
Slide switches (SW1-1/SW1-2)
The combination of SW1-1 and SW1-2 enables you to switch communication method and set the test operation mode
(enabled/disabled). The following table lists the combinations of the switches.
In the test operation mode, the functions such as JOG operation, positioning operation, and machine analyzer are available
with MR Configurator2.
*1 In the case of CC-Link IE Field Network Basic, motor driving by test operation from MR Configurator2 via an Ethernet connection is
possible. Once the test operation mode is entered, the servo amplifier will not receive controller commands until the power of the servo
amplifier is cycled.
Rotary switches (SW2/SW3)
Set the identification number of the servo amplifier in hexadecimal. From "00h (0)" to "FFh (255)" can be set. The set value is
used as the 4th octet of the IP address when the identification number is set between "01h (1)" and "FFh (255)".
Slide switches (SW1)
Communication
Test operation mode
CC-Link IE Field Network
Disabled
CC-Link IE Field Network Basic
Disabled
Not available
Enabled
For manufacturer setting
1
ON
2
1
ON
2
1
ON
2
1
ON
2