1 CC-Link IE TSN
1.3 Application function
13
1
IP address setting function
IP addresses are delivered from the controller to servo amplifiers via CC-Link IE TSN.
Set the IP address required for CC-Link IE TSN communication from the following items. The IP address range is between
0.0.0.1 and 223.255.255.254. Set the IP address within the range.
The initial value of the IP address is as follows.
[Pr. NPA01 IP address setting]
Rotary switches (SW1/SW2)
IP address
"00000000h" (The rotary switch is
used.)
00h
1st octet
Use the value of/for [Pr. NPA02 IP address].
2nd octet
3rd octet
4th octet
01h to FEh
1st octet
Use the 1st to 3rd octet values of [Pr. NPA02 IP address].
2nd octet
3rd octet
4th octet
The setting value of the rotary switch (SW1/SW2) is used.
FFh
Not available.
"00000001h" (Network parameters are
used.)
1st octet
Use the value of/for [Pr. NPA02 IP address].
2nd octet
3rd octet
4th octet
Item
Initial value
IP address
192.168.3.1
Subnet mask
255.255.255.0