6 OPTIONS AND PERIPHERAL EQUIPMENT
6.11 Power factor improving DC reactor
209
6
6.11
Power factor improving DC reactor
Advantages
• It improves the power factor by increasing the form factor of the servo amplifier's input current.
• It decreases the power supply capacity.
• The input power factor is improved to about 85 %.
• As compared to the power factor improving AC reactor (FR-HAL-(H)), it decreases the loss.
Restrictions
When connecting the power factor improving DC reactor to the servo amplifier, disconnect P3 and P4. If it remains connected,
the effect of the power factor improving DC reactor is not produced.
When used, the power factor improving DC reactor generates heat. To dissipate heat, therefore, maintain a minimum
clearance of 10 cm each at the top and bottom, and 5 cm at the sides.
200 V class
*1 Use this for grounding.
*2 When using the power factor improving DC reactor, remove the short-circuit bar between P3 and P4.
*3 Maximum dimensions. The dimensions vary depending on the curvature of the input/output lines.
*4 Selection conditions of wire size are as follows.
Wire type: 600 V Grade heat-resistant polyvinyl chloride insulated wire (HIV wire)
Construction requirements: Single wire set in midair
Servo amplifier
Power factor
improving
DC reactor
Dimensions [mm]
Terminal
size
Mass
[kg]
Wire [mm
2
W
W1
H
D
D1
D2
D3
d
MR-J5-10_
MR-J5-20_
FR-HEL-0.4K
70
60
71
61
21
M4
M4
0.4
2 (AWG 14)
MR-J5-40_
FR-HEL-0.75K
85
74
81
61
21
M4
M4
0.5
MR-J5-60_
MR-J5-70_
FR-HEL-1.5K
85
74
81
70
30
M4
M4
0.8
MR-J5-100_
FR-HEL-2.2K
85
74
81
70
30
M4
M4
0.9
W ± 2
W1
H
P
P1
*2
P3
P4
FR-HEL
2-d mounting hole
(Varnish is removed only from right (face and back side))
*1
D or less
Servo amplifier
5 m or less
Summary of Contents for Melservo-J5 MR-J5 Series
Page 2: ......
Page 441: ...12 USING A FULLY CLOSED LOOP SYSTEM 12 7 Absolute position detection system 439 12 MEMO ...
Page 445: ......