236
6 OPTIONS AND PERIPHERAL EQUIPMENT
6.12 Power factor improving AC reactor
200 V class [G] [A]
*1 Use this for grounding.
*2 For FR-HAL-0.4K to FR-HAL-1.5K, the W dimension is "W ± 2".
*3 For 1-phase 200 V AC to 240 V AC power supply, connect the power supply to L1 and L3. Leave L2 open.
*4 Maximum dimensions. The dimensions vary depending on the curvature of the input/output lines.
Servo amplifier
Power factor
improving
AC reactor
Dimensions [mm]
Terminal
size
Mass [kg]
W
W1
H
D1
D2
d
MR-J5-10_
MR-J5-20_
FR-HAL-0.4K
104
84
99
72
51
40
M5
M4
0.6
MR-J5-40_
FR-HAL-0.75K
104
84
99
74
56
44
M5
M4
0.8
MR-J5-60_
MR-J5-70_
FR-HAL-1.5K
104
84
99
77
61
50
M5
M4
1.1
MR-J5-100_
(3-phase power
supply input)
FR-HAL-2.2K
40
115
77
71
57
M6
M4
1.5
MR-J5-100_
(1-phase power
supply input)
MR-J5-200_
(3-phase power
supply input)
FR-HAL-3.7K
40
115
83
81
67
M6
M4
2.2
MR-J5-200_
(1-phase power
supply input)
FR-HAL-5.5K
40
115
83
81
67
M6
M4
2.3
R X
Z
S Y T
W1
D1
D2
H
Y
Z
S
T
MC
MCCB
FR-HAL
X
R
L1
L2
L3
L1
L2
L3
Y
Z
S
T
MC
MCCB
FR-HAL
X
R
Servo amplifier
3-phase 200 V class
Terminal assignment
4-d mounting hole
(Varnish is removed only from bottom right
(face and back side))
*1
3-phase
200 V AC to 240 V AC
D or less
Servo amplifier
1-phase 200 V class
1-phase
*3
200 V AC to 240 V AC
W or less
*2
Summary of Contents for MELSERVO-J5 MR-J5-G Series
Page 2: ......
Page 473: ...12 USING A FULLY CLOSED LOOP SYSTEM 12 7 Absolute position detection system 471 12 MEMO ...