6 OPTIONS AND PERIPHERAL EQUIPMENT
6.2 Regenerative option
177
6
6.2
Regenerative option
Combination and regenerative power
The power values in the table are resistor-generated powers and not rated powers.
200 V class
*1 Install a cooling fan when using this regenerative option.
*2 Depending on the operating conditions, a cooling fan must be installed.
Page 185 Connection of regenerative option
*3 Available on servo amplifiers with firmware version B6 or later.
400 V class
*1 Always install a cooling fan.
Servo
amplifier
Regenerative power [W]
Built-in
regenerative
resistor
MR-
RB032
[40
Ω
]
MR-
RB12
[40
Ω
]
MR-
RB14
[26
Ω
]
MR-
RB30
[13
Ω
]
MR-
RB3N
[9
Ω
]
MR-
RB31
[6.7
Ω
]
MR-
RB3Z
[5.5
Ω
]
MR-
RB34
[26
Ω
]
MR-
RB50
[13
Ω
]
MR-
RB5N
[9
Ω
]
MR-
RB51
[6.7
Ω
]
MR-
RB5Z
[5.5
Ω
]
MR-J5-10_
30
MR-J5-20_
10
30
100
MR-J5-40_
10
30
100
MR-J5-60_
10
20
100
MR-J5-70_
30
100
300
MR-J5-100_
30
100
300
MR-J5-200_
100
300
500
MR-J5-350_
100
300
500
MR-J5-500_
130
300
500
MR-J5-700_
170
300
500
MR-J5W2-
22G_
20
100
MR-J5W2-
44G_
20
100
MR-J5W2-
77G_
100
300
MR-J5W2-
1010G_
100
300
MR-J5W3-
222G_
30
100
300
MR-J5W3-
444G_
30
100
300
Servo amplifier
Regenerative power [W]
Built-in
regenerative
resistor
MR-RB1H-4
[82
Ω
]
MR-RB3M-4
[120
Ω
MR-RB3G-4
[47
Ω
]
MR-RB5G-4
[47
Ω
MR-RB3Y-4
[36
Ω
MR-RB5Y-4
[36
Ω
]
MR-J5-60_4_
15
100
300
MR-J5-100_4_
15
100
300
MR-J5-200_4_
100
300
500
MR-J5-350_4_
120
300
500
Summary of Contents for MELSERVO-J5 MR-J5-G Series