11 OPTIONS AND PERIPHERAL EQUIPMENT
11.11 Power factor improving DC reactors
409
11
400 V class
*1 Use this for grounding.
*2 When using the power factor improving DC reactor, remove the short bar between P3 and P4.
*3 Selection conditions of wire size are as follows.
Wire type: 600 V Grade heat-resistant polyvinyl chloride insulated wire (HIV wire)
Construction condition: Single wire set in midair
Servo amplifier
Power factor
improving
DC reactor
Dimensions [mm]
Terminal
size
Mass
[kg]
Wire [mm
2
W
W1
H
D
D1
D2
D3
d
MR-J4-60GF4(-RJ)
FR-HEL-H1.5K
66
50
100
80
74
54
37
M4
M3.5
1.0
2 (AWG 14)
MR-J4-100GF4(-RJ)
FR-HEL-H2.2K
76
50
110
80
74
54
37
M4
M3.5
1.3
2 (AWG 14)
W1
D2
W ± 2.5
H ± 2.5
D or less
(D3)
D1 ± 1
4-d mounting hole
*1
P P1
*2
Servo amplifier
P3
P4
FR-HEL-H
5 m or less