
46
4 PROCEDURE BEFORE OPERATION
4.4 Setting Channel Numbers
Precautions for turning on
• Turn off the power for the system in all phases before installing the board to or removing it from the personal computer.
Failure to do so may result in electric shock or cause the board to fail or malfunction.
Precautions for installing the board
• Fix the board by tightening the board-fixing screws within the specified torque range. Undertightening may cause drop,
short circuit, or malfunction. Overtightening may damage the screw and/or board, resulting in drop, short circuit, or
malfunction. For the tightening torque of the board-fixing screws, refer to the manual supplied with the personal computer.
• Before handling the board, touch a conducting object such as a grounded metal to discharge the static electricity from the
human body. Failure to do so may cause the board to fail or malfunction.
• Install the board to a personal computer which is compliant with PCI standard or PCI Express
standard (
Operating Environment). Failure to do so may cause a failure or malfunction.
• Securely insert the board into the PCI slot following the board installation instruction of the personal computer. Incorrect
insertion of the board may cause malfunction, failure, or drop of the board.
• When installing the board, take care not to get injured by an implemented component or a surrounding member.
• When installing the board, take care not to contact with other boards.
4.4
Setting Channel Numbers
Channel number is set per board, and used to identify the board. 181 is set for the board channel number as a factory default
and the range of 181 to 184 can be set.
Channel numbers being set are used to specify the target boards in setting parameters and performing the MELSEC data link
library function. When using two or more boards in a single personal computer, set channel numbers not to overlap.
Setting method
Set the channel numbers on the "Channel No. Setting" screen in CC IE Field Utility.
(
Page 112 Setting Board Channel Numbers)
Channel numbers set on the "Channel No. Setting" screen is saved to the CC-Link IE Field Network board.
The channel numbers being set are retained when performing the following operations.
• Rebooting a personal computer
• Board installation position change
• Board replacement to another personal computer
Summary of Contents for MELSEC Q80BD-J71GF11-T2
Page 2: ......
Page 6: ...4 Disposal Precautions CAUTION When disposing of this product treat it as industrial waste ...
Page 118: ...116 12 MONITORING MEMO ...
Page 140: ...138 14 MELSEC DATA LINK LIBRARY MEMO ...
Page 142: ...140 15 PROGRAMMING 15 1 Precautions on Programming MEMO ...
Page 243: ...241 I U Utility 83 ...
Page 247: ......