![Mitsubishi Electric MELSEC Q80BD-J71GF11-T2 User Manual Download Page 33](http://html.mh-extra.com/html/mitsubishi-electric/melsec-q80bd-j71gf11-t2/melsec-q80bd-j71gf11-t2_user-manual_238449033.webp)
2 SYSTEM CONFIGURATION
2.4 Operating Environment
31
2
2.4
Operating Environment
The following table shows the operating environment for the CC-Link IE Field Network board.
*1 Apply Windows Updates (KB4132216, KB4091664, KB4465659, and KB4480977).
*2 64-bit version only
*3 Apply Service Pack1 and Security Update for Windows (KB3033929). Otherwise, use SW1DNC-CCIEF-B Version 1.09K or earlier.
*4 32-bit version only
For the information on how to obtain SW1DNC-CCIEF-B version 1.09K or earlier, refer to the following
section.
Page 224 Restrictions for Operating System
Item
Description
Personal computer
A personal computer on which Microsoft
Windows
operates
CPU
System requirements of the operating system must be met.
Required memory
PCI bus specifications
For Q80BD-J71GF11-T2
• Compliant with PCI standard Rev.2.2 (3.3 VDC/5 VDC, 32-bit bus, Reference clock 33 MHz)
PCI Express
bus specifications
For Q81BD-J71GF11-T2
• Compliant with PCI Express standard Rev.1.1 (3.3 VDC, Link width 1 lane, Reference clock 100 MHz)
Available hard disk capacity
1GB or more
Disk drive
CD-ROM disk drive
Monitor
Resolution: 1024
×
768 dots or higher
Operating system (English version)
• Windows Server
2019 (Standard)
• Windows Server 2016 (Standard)
• Windows 10 (Home, Pro, Enterprise, Education, IoT Enterprise 2016 LTSB
• Windows 8.1, Windows 8.1 (Pro, Enterprise)
• Windows Server 2012 R2 (Standard)
• Windows 8, Windows 8 (Pro, Enterprise)
• Windows Server 2012 (Standard)
• Windows 7 (Home Premium, Professional, Ultimate, Enterprise)
• Windows Server 2008 R2 (Standard, Enterprise)
When using any of the following operating systems, use SW1DNC-CCIEF-B with the version 1.09K or earlier.
• Windows Server 2008 (Standard (x86, x64), Enterprise (x86, x64))
• Windows Vista
(Home Basic, Home Premium, Ultimate, Business, Enterprise) SP2 or later
• Windows Server 2003 R2 (Standard (x86, x64), Enterprise Edition (x86, x64)) SP2 or later
• Windows XP
(Professional, Home Edition) SP3 or later
Programming language (English
version)
Visual Basic
and Visual C++
in the following Microsoft Visual Studio
:
Visual Studio 2017, Visual Studio 2015, Visual Studio 2013, Visual Studio 2012, Visual Studio 2010,
Visual Studio 2008, Visual Studio 2005, Visual Studio .NET 2003
Summary of Contents for MELSEC Q80BD-J71GF11-T2
Page 2: ......
Page 6: ...4 Disposal Precautions CAUTION When disposing of this product treat it as industrial waste ...
Page 118: ...116 12 MONITORING MEMO ...
Page 140: ...138 14 MELSEC DATA LINK LIBRARY MEMO ...
Page 142: ...140 15 PROGRAMMING 15 1 Precautions on Programming MEMO ...
Page 243: ...241 I U Utility 83 ...
Page 247: ......