![Mitsubishi Electric MELSEC Q80BD-J71GF11-T2 User Manual Download Page 221](http://html.mh-extra.com/html/mitsubishi-electric/melsec-q80bd-j71gf11-t2/melsec-q80bd-j71gf11-t2_user-manual_238449221.webp)
APPX
Appendix 7 Comparison of CC-Link and CC-Link IE Field Network
219
A
Appendix 7
Comparison of CC-Link and CC-Link IE
Field Network
This section explains the differences in the specifications between CC-Link Ver.2 board and CC-Link IE Field Network board.
Performance specifications comparison
■
Transmission and interface specifications
*1 These are values in remote net ver.2 mode or remote net additional mode.
■
Hardware specifications
Item
Specifications
CC-Link Ver.2 board
CC-Link IE Field Network board
Maximum link points per network
RWw
2048 points
8192 points
RWr
2048 points
8192 points
RX
8192 points
16384 points
RY
8192 points
16384 points
Maximum number of
send points per
station
Master station
RWw
2048 points
8192 points
RY
8192 points
16384 points
Local station
RWw
128 points
Online (Normal mode): 1024 points
Online (High speed mode): 256 points
RY
896 points
2048 points
Transmission
specifications
Communication speed
Selectable from 156 kbps/625 kbps/
2.5 Mbps/5 Mbps/10 Mbps
1 Gbps
Connection cable
CC-Link dedicated cable
CC-Link dedicated high-
performance cable
Ver.1.10- compatible CC-Link
dedicated cable
An Ethernet cable that meets the 1000BASE-T standard:
Category 5e or higher (double shielded, STP), straight
cable
(
Maximum station-to-station
distance
30 cm to 1200 m (varies depending
on connected stations and
transmission speed)
100 m (compliant with ANSI/TIA/EIA-568-B (Category 5e))
(
Page 52 Ethernet cable connection)
Overall cable distance
1200 m (at transmission speed of
156 kbps)
Line topology: 12000 m (when connected to 1 master
station and 120 slave stations)
Star topology: Depends on the system configuration
Ring topology: 12100 m (when connected to 1 master
station and 120 slave stations)
Network topology
Bus topology
Line topology, star topology (coexistence of line topology
and star topology is possible.), ring topology
Number of connected
stations in one
network
Master station
1 station (up to 64 remote stations
can be connected to master station)
1 station (up to 120 slave stations can be connected to
master station)
Local station
26 stations
120 stations
Station type
Master station, local station
Communication method
Broadcast polling
Token passing method
Number of occupied I/O points
32 points (I/O assignment: Intelligent 32 points)
Item
Specifications
CC-Link Ver.2 board
CC-Link IE Field Network board
Q80BD-
J61BT11N
Q81BD-J61BT11
Q80BD-J71GF11-T2
Q81BD-J71GF11-T2
Internal current
consumption
0.56 A (5 VDC)
1.06 A (3.3 VDC)
1.10 A (5 VDC)
1.68 A (3.3 VDC)
Installation slot
PCI slot
PCI Express slot
PCI bus slot, PCI-X slot
PCI Express slot
Standard
Low profile
External dimensions
121(H)
×
19(W)
×
153(D) [mm]
121(H)
×
18.5(W)
×
181(D)
[mm]
121(H)
×
18.5(W)
×
181(D)
[mm]
80(H)
×
18.5(W)
×
181(D)
[mm]
Weight
0.11 kg
0.11 kg
0.08 kg
0.07 kg
Summary of Contents for MELSEC Q80BD-J71GF11-T2
Page 2: ......
Page 6: ...4 Disposal Precautions CAUTION When disposing of this product treat it as industrial waste ...
Page 118: ...116 12 MONITORING MEMO ...
Page 140: ...138 14 MELSEC DATA LINK LIBRARY MEMO ...
Page 142: ...140 15 PROGRAMMING 15 1 Precautions on Programming MEMO ...
Page 243: ...241 I U Utility 83 ...
Page 247: ......