418
6 MANUAL CONTROL
6.1 JOG Operation
Simultaneous start
Simultaneous start JOG operation for specified multiple axes.
Processing details
• JOG operation continues at the JOG speed setting register value for each axis while the "[Rq.1124] JOG operation
simultaneous start command (R: M30048/Q: M2048)" turns on, and a deceleration stop is made by the "[Rq.1124] JOG
operation simultaneous start command (R: M30048/Q: M2048)" OFF. Control of acceleration/deceleration is based on the
data set in the JOG operation data.
• JOG operation axis is set in the "[Cd.1096] JOG operation simultaneous start axis setting register (forward JOG) (R:
D35286 to D35289/Q: D710, D711)" / "[Cd.1097] JOG operation simultaneous start axis setting register (reverse JOG) (R:
D35290 to D35293/Q: D712, D713)".
• The setting range for "[Cd.1110] JOG speed setting (R: 2n, 2n/Q: D640+2n, D641+2n)" are shown below.
*1 When the "speed control 10
multiplier setting for degree axis" is set to "valid" in the fixed parameter, the unit is "
10
-2
[degree/min]".
Device name
Setting range
mm
inch
degree
pulse
[Cd.1110]JOG speed setting
(R: 2n, 2n/
Q: D640+2n, D641+2n)
1 to 600000000
(
10
-2
[mm/min])
1 to 600000000
(
10
-3
[inch/min])
1 to 2147483647
(
10
-3
[degree/min])
1 to 2147483647
[pulse/s]
Deceleration stop based
on JOG operation data
t
V
Acceleration based
on JOG operation data
JOG operation speed
OFF
ON
[Rq.1124] JOG operation simultaneous start command
(R: M30048/Q: M2048)
[Cd.1096] JOG operation simultaneous start axis setting
register (forward JOG) (R: D35286 to D35289/Q: D710, D711)/
[Cd.1097] JOG operation simultaneous start axis setting
register (reverse JOG) (R: D35290 to D35293/Q: D712, D713)
JOG operation by data on JOG operation
simultaneous start axis setting register
Axis
16
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
Axis
15
Axis
14
Axis
13
Axis
12
Axis
11
Axis
10
Axis
9
Axis
8
Axis
7
Axis
6
Axis
5
Axis
4
Axis
3
Axis
2
Axis
1
Axis
32
R: D35286/
Q: D710
R: D35287/
Q: D711
Axis
31
Axis
30
Axis
29
Axis
28
Axis
27
Axis
26
Axis
25
Axis
24
Axis
23
Axis
22
Axis
21
Axis
20
Axis
19
Axis
18
Axis
17
Axis
48
Axis
47
Axis
46
Axis
45
Axis
44
Axis
43
Axis
42
Axis
41
Axis
40
Axis
39
Axis
38
Axis
37
Axis
36
Axis
35
Axis
34
Axis
33
Axis
64
R: D35288
R: D35289
Axis
63
Axis
62
Axis
61
Axis
60
Axis
59
Axis
58
Axis
57
Axis
56
Axis
55
Axis
54
Axis
53
Axis
52
Axis
51
Axis
50
Axis
49
[Cd.1096] JOG operation
simultaneous start axis
setting registers
(Forward rotation JOG)
Axis
16
Axis
15
Axis
14
Axis
13
Axis
12
Axis
11
Axis
10
Axis
9
Axis
8
Axis
7
Axis
6
Axis
5
Axis
4
Axis
3
Axis
2
Axis
1
Axis
32
R: D35290/
Q: D712
R: D35291/
Q: D713
Axis
31
Axis
30
Axis
29
Axis
28
Axis
27
Axis
26
Axis
25
Axis
24
Axis
23
Axis
22
Axis
21
Axis
20
Axis
19
Axis
18
Axis
17
Axis
48
Axis
47
Axis
46
Axis
45
Axis
44
Axis
43
Axis
42
Axis
41
Axis
40
Axis
39
Axis
38
Axis
37
Axis
36
Axis
35
Axis
34
Axis
33
Axis
64
R: D35292
R: D35293
Axis
63
Axis
62
Axis
61
Axis
60
Axis
59
Axis
58
Axis
57
Axis
56
Axis
55
Axis
54
Axis
53
Axis
52
Axis
51
Axis
50
Axis
49
[Cd.1097] JOG operation
simultaneous start axis
setting registers
(Reverse rotation JOG)
*1: Make JOG operation simultaneous start axis setting with 1/0.
1: Simultaneous start execution
0: Simultaneous start not execution
*2: The following range is valid. R16MTCPU: Axis No.1 to 16, R32MTCPU: Axis No.1 to 32.