102
2 POSITIONING DEDICATED SIGNALS
2.2 Data Registers
[Md.1027] Servo amplifier Vendor ID (R: 48n/Q: #8016+20n)
This register stores the servo amplifier vendor ID for each axis when the control circuit power supply of the servo amplifier is
turned ON.
The contents are not cleared when the control circuit power supply of the servo amplifier is turned OFF.
[Md.108] Servo status1 (R: 48n/Q: #8010+20n)
This register stores the servo status read from the servo amplifier.
*1 The status of control mode (b2, b3) are as follows.
Servo warning (b15) turns ON during Motion controller forced stop or servo forced stop.
Monitor value
Description
0
Mitsubishi Electric Corporation
3
ORIENTAL MOTOR Co., Ltd.
8
CKD Nikki Denso Co., Ltd.
10
IAI Corporation
Item
Description
READY ON (b0)
Indicates the ready ON/OFF.
Servo ON (b1)
Indicates the servo ON/OFF.
Control mode (b2, b3)
Indicates the control mode of servo amplifier.
Gain changing (b4)
Turns ON when servo amplifier is gain changing.
Fully closed control changing (b5)
Turns ON when servo amplifier is fully closed control changing.
Servo alarm (b7)
Turn ON during the servo alarm.
In-position (b12)
The dwell pulse turns ON within the servo parameter "in-position".
Torque limit (b13)
Turns ON when the servo amplifier is having the torque restricted.
Absolute position lost (b14)
Turns ON when the servo amplifier is lost the absolute position.
Servo warning (b15)
Turn ON during the servo warning.
b3
b2
Control mode
0
0
Position control mode
0
1
Speed control mode
1
0
Torque control mode
b14
b15
b13 b12 b11 b10 b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
[Md.108] Servo status 1
(R: 48n/Q: #8010+20n)
READY ON
Servo ON
Control mode
Gain changing
Fully closed control changing
Servo alarm
In-position
Torque limit
Absolute position lost
Servo warning
*: The 0/1 is stored in the servo status 1.
0: OFF
1: ON