12 DATA USED FOR POSITIONING CONTROL
12.7 Monitor Data
457
12
[Md.29] Speed-position switching control positioning amount
This area stores the movement amount for the position control to end after the control is switched to the position control with
the speed-position switching control. Multiplying the stored value by the following converted value enables the monitoring of
the converted value in each unit.
When [Da.2] Control method is the speed-position switching control (reverse run), a negative value is stored.
■
Buffer memory address
The following table shows the buffer memory address of this area.
[Md.30] External I/O signal
This area stores the on/off state of external I/O signals.
Values are stored in the bits corresponding to each external I/O signal. The following table shows the assignment of each
external I/O signal.
The update cycle of this area is 0.88ms.
■
Buffer memory address
The following table shows the buffer memory address of this area.
If 1: Pre-analysis mode is set for [Cd.43] Analysis mode setting and Positioning start signal [Y10, Y11, Y12,
Y13] is used as the start trigger, the external command signal (CHG) is disabled from when the positioning
data analysis starts until a pulse input starts by inputting the start trigger. Thus, the external command signal
([Md.30] External I/O signal: b4) is fixed to 0 during that time.
Unit
Converted value
m
10
-1
inch
10
-5
degree
10
-5
pulse
1
Buffer memory name
Axis 1
Axis 2
Axis 3
Axis 4
[Md.29] Speed-position switching control positioning amount
814
914
1014
1114
815
915
1015
1115
External I/O signal
Stored value
OFF
0
ON
1
Buffer memory
Assignment of I/O signals
b0
Lower limit signal
b1
Upper limit signal
b2
Drive unit READY signal
b3
Stop signal
b4
External command signal
b5
Zero signal
b6
Near-point dog signal
b7
Use prohibited (fixed to 0)
b8
Deviation counter clear signal
b9 to b15
Use prohibited (fixed to 0)
Buffer memory name
Axis 1
Axis 2
Axis 3
Axis 4
[Md.30] External I/O signal
816
916
1016
1116
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b0
b1
b2
b3
b4
0
0
0
0
0
0
0
0
Summary of Contents for MELSEC iQ-R RD75P4
Page 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Page 2: ......
Page 13: ...11 MEMO ...
Page 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Page 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Page 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Page 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Page 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Page 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Page 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Page 597: ......