356
12 DATA USED FOR POSITIONING CONTROL
12.1 Types of Data
Setting items for positioning data
Positioning data must be set to perform Major positioning control. The following table lists the setting items for Positioning
data.
One to 600 items of Positioning data can be set for each axis.
: Always set,
: Set as required
: Setting not possible (If these items are set, Continuous path control not possible (Error code: 1A1EH, 1A1FH) occurs at
the start.)
: Setting not required (The set value is ignored. Set the value within the setting range, such as the initial value.)
*1 Two control methods are available: Absolute (ABS) system and Incremental (INC) system.
*2 Set an M code for the reference axis and set the number of pitches for the linear interpolation axis.
Setting items for positioning data
Position control
Speed control
Speed-
position
switching
control
1-axis linear
control
2-axis linear
interpolation
control
3-axis linear
interpolation
control
4-axis linear
interpolation
control
1-axis fixed-
feed control
2-axis fixed-
feed control
3-axis fixed-
feed control
4-axis fixed-
feed control
2-axis
circular
interpolation
control
3-axis
helical
interpolation
control
1-axis speed
control
2-axis speed
control
3-axis speed
control
4-axis speed
control
[Da.1]
Operation
pattern
Independent
positioning control
(positioning
complete)
Continuous
positioning control
Continuous path
control
[Da.2]
Control method
Line 1
Line 2
Line 3
Line 4
Fixed-feed 1
Fixed-feed 2
Fixed-feed 3
Fixed-feed 4
Circular sub
Circular right
Circular left
Helical sub
Helical right
Helical left
Forward run speed 1
Reverse run speed 1
Forward run speed 2
Reverse run speed 2
Forward run speed 3
Reverse run speed 3
Forward run speed 4
Reverse run speed 4
Forward run
speed-
position
Reverse run
speed-
position
[Da.3]
Acceleration time No.
[Da.4]
Deceleration time No.
[Da.5]
Axis to be interpolated
: 2-axis interpolation control, 3-axis helical interpolation control
: 1-axis control, 3-axis interpolation control, 4-axis interpolation control
[Da.6]
Positioning address/movement
amount
[Da.7]
Arc address
[Da.8]
Command speed
[Da.9]
Dwell time
[Da.10]
M code
[Da.27]
M code ON signal output timing
[Da.28]
ABS direction in degrees
[Da.29]
Interpolation speed specification
method
: 1-axis control,
: 2-axis interpolation control, 3-axis interpolation control, 4-axis interpolation control
Summary of Contents for MELSEC iQ-R RD75P4
Page 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Page 2: ......
Page 13: ...11 MEMO ...
Page 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Page 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Page 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Page 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Page 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Page 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Page 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Page 597: ......