8 COMMON FUNCTIONS
8.1 Overview of Common Functions
303
8
8
COMMON FUNCTIONS
This chapter describes the details and usage of the common functions executed according to the user's requirements.
Common functions include the functions required for using the RD75 such as the module data initialization function and
module data backup function.
Check the setting and execution procedures for each common function, and execute an appropriate function as required.
8.1
Overview of Common Functions
Functions below referred to as Common function can be used as required regardless of the control method used. These
common functions are executed by engineering tools or with programs.
The following table shows the functions included in the common functions.
Common function
Description
Module data initialization function
Sets module parameters and module extension parameters (positioning data and block start data) in the buffer memory
and setting values in the module extension parameter file to their factory default settings.
Module data backup function
Saves the module extension parameters (positioning data and block start data) in the buffer memory currently being used
in control into the module extension parameter file.
External I/O signal logic switching
function
Switches I/O signal logics according to the equipment connected to the RD75. For the system in which signals handled
as normally closed contacts (such as Drive unit READY signal and limit signals) are not used, the parameter logic setting
can be controlled without wiring if the setting is changed to "Positive logic".
External I/O signal monitor function
Monitors External I/O signal using the module's detailed information which can be displayed on the system monitor of an
engineering tool.
History monitor function
Monitors the error history, warning history, and start history of all axes.
Amplifier-less operation function
Performs positioning controls without a drive unit. This function is used for debugging user programs at a start-up or
simulating positioning operation.
Online module change
Allows the module change without stopping the system. For the online module change procedure, refer to the following.
MELSEC iQ-R Online Module Change Manual
Summary of Contents for MELSEC iQ-R RD75P4
Page 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Page 2: ......
Page 13: ...11 MEMO ...
Page 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Page 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Page 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Page 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Page 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Page 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Page 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Page 597: ......