7 CONTROL SUB FUNCTIONS
7.2 Sub Functions Specific to Machine OPR
211
7
7.2
Sub Functions Specific to Machine OPR
The sub functions specific to machine OPR include OPR retry function and OP shift function. Each function is executed based
on the parameter setting.
OPR retry function
If a workpiece passes over the OP without stopping during the position control, the workpiece may not move back in the
direction of the OP although the machine OPR is commanded, depending on the workpiece position. In this case, the
workpiece has to be moved to a position before the near-point dog by the JOG operation or other operations to start the
machine OPR again. However, by using the OPR retry function, the machine OPR can be performed regardless of the
workpiece position.
Control details
The following shows the operation of the OPR retry function.
■
OPR retry operation when the workpiece is within the range between the upper/lower limits
(1)
The movement starts in the direction set in [Pr.44] OPR direction by Machine OPR start.
(2)
The operation decelerates when Limit signal OFF is detected.
(3)
After the operation has stopped due to the detection of Limit signal OFF, the operation moves at the speed set in [Pr.46] OPR speed in the direction
opposite to the direction set in [Pr.44] OPR direction.
(4)
The operation decelerates when Near-point dog signal is turned off.
(5)
After the operation has stopped due to turning off of Near-point dog signal, the machine OPR is performed in the direction set in [Pr.44] OPR direction.
(6)
Machine OPR is completed.
ON
(5)
(1)
(2)
(3)
(6)
(4)
Near-point dog
Limit signal OFF state
Zero signal
Summary of Contents for MELSEC iQ-R RD75P4
Page 1: ...MELSEC iQ R Positioning Module User s Manual Application RD75P2 RD75P4 RD75D2 RD75D4 ...
Page 2: ......
Page 13: ...11 MEMO ...
Page 19: ...17 CONTENTS INDEX 588 REVISIONS 592 WARRANTY 593 TRADEMARKS 594 ...
Page 498: ...496 13 PROGRAMMING 13 2 List of Labels Used ...
Page 503: ...13 PROGRAMMING 13 4 Program Example 501 13 ...
Page 514: ...512 13 PROGRAMMING 13 4 Program Example Restart program Parameter data initialization program ...
Page 515: ...13 PROGRAMMING 13 4 Program Example 513 13 Flash ROM write program Error reset program ...
Page 516: ...514 13 PROGRAMMING 13 4 Program Example Stop program ...
Page 565: ...APPENDICES Appendix 4 Operation Examples of When the Remote Head Module Is Mounted 563 A ...
Page 597: ......