16 POSITIONING INSTRUCTION
16.2 Positioning Module
887
16
■
Control data
Processing details
• The data of "[Md.20] Current feed value" of one of the following target axes is set in the positioning or arc address. The
positioning data other than the positioning or arc address must be set using the engineering tool or program.
• Positioning data No.1 to 600 can be taught.
• To move to an address (position) to be set as the positioning or arc address of the positioning data, JOG, inching, or manual
pulse operation is used.
• Whether the GP.TEACH
instruction has been completed normally or with an error can be checked with the completion
device (d) or completion status indication device (d)+1.
• The following figure shows the operation at completion of the GP.TEACH
instruction.
• For details of the function, refer to
MELSEC iQ-F FX5 User's Manual (Positioning Control - Intelligent function module).
Device
Item
Description
Setting range
Set by
(s)+0
System area
(s)+1
Completion status
The instruction completion status is stored.
• 0: Normal
• Other than 0: Error (error code)
System
(s)+2
Teaching data selection
Selects the address to which to write the current feed value (positioning or arc
address).
• 0: Writes the current feed value to the positioning address.
• 1: Writes the current feed value to the arc address.
0, 1
User
(s)+3
Positioning data
number
Sets the positioning data number at which to perform the teaching.
1 to 600
User
Instruction symbol
Target axis
GP.TEACH1
Axis 1
GP.TEACH2
Axis 2
Device
Description
Completion device (d)
This device turns on during the END processing of the scan where the GP.TEACH
instruction completed, and
turns off during the next END processing.
Completion status indication device (d)+1
This device turns on or off depending on the completion status of the GP.TEACH
instruction.
When completed normally: Unchanged from off.
When completed with an error: Turns on during the END processing of the scan where the GP.TEACH
instruction completed, and turns off during the next END processing.
END
0
END
0
END
0
END
0
END
0
OFF
OFF
OFF
OFF
ON
ON
Sequence scan
GP.TEACH
instruction
Completion device(d)
Completion status
indication device (d1)+1
When completed with an error
Instruction execution
When completed
normally
1 scan
Instruction execution complete
Summary of Contents for MELSEC iQ-F FX5
Page 1: ...MELSEC iQ F FX5 Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 17: ...15 CONTENTS ...
Page 24: ...22 MEMO ...
Page 1050: ...1048 26 TIME DATA FUNCTIONS 26 4 Division MEMO ...
Page 1068: ...1066 29 COUNTER FUNCTION BLOCKS 29 4 Counter Function Block Operation error There is no error ...
Page 1107: ...I 1105 MEMO ...
Page 1111: ......