8 APPLICATION INSTRUCTION
8.8 Character String Operation Instruction
Converting 16-bit binary data to decimal ASCII
BINDA(P)(_U)
These instructions convert 16-bit binary data specified by (s) into decimal ASCII codes, and store the converted data in the
device specified by (d) and later.
Setting data
■
Descriptions, ranges, and data types
■
Applicable devices
*1 T, ST, C cannot be used.
Processing details
• These instructions convert 16-bit binary data specified by (s) into decimal ASCII codes, and store the converted data in the
device specified by (d) and later.
Ex.
When -12345 is specified in (s) (when signed data is specified)
• The following shows the operation result to be stored in (d).
Ladder diagram
Structured text
ENO:=BINDA(EN,s,d);
ENO:=BINDAP(EN,s,d)
ENO:=BINDA_U(EN,s,d);
ENO:=BINDAP_U(EN,s,d)
FBD/LD
Operand
Description
Range
Data type
Data type (label)
(s)
BINDA(P)
Binary data to be converted into ASCII codes
-32768 to +32767
16-bit signed binary
ANY16_S
BINDA(P)_U
0 to 65535
16-bit unsigned binary
ANY16_U
(d)
Head device number storing conversion result
Character string
ANYSTRING_SINGLE
EN
Execution condition
Bit
BOOL
ENO
Execution result
Bit
BOOL
Operand
Bit
Word
Double word Indirect
specification
Constant
Others
X, Y, M, L, SM,
F, B, SB, S
T, ST, C, D, W,
SD, SW, R
U
\G
Z
LC
LZ
K, H
E
$
(s)
(d)
• As sign data, "20H" is stored if the 16-bit binary data is positive, and "2DH" is stored if the data is negative.
• "20H" is stored for "0" on the left side of the valid digits (zero suppression). For "00325", 20H is stored for "00", and the number of digits is 3 based on
"325".
• In the device specified by (d)+3, 0 is stored when SM701 (output character number selector signal) is off, and the original data remains when SM701 is
on.
(s)
(d)
EN
ENO
d
s
(d)
(d)+1
(d)+2
(d)+3
b15
b0
b7
b8
b0
b15
(s)
0
ASCII code for ten-thousands place
ASCII code for hundreds place
ASCII code for ones place
ASCII code for sign
ASCII code for thousands place
ASCII code for tens place
BIN16
"0" is stored only
when SM701 is off.
(d)
(d)+1
(d)+2
(d)+3
b15
b0
b7
b8
b0
b15
(s)
31H (1)
2DH (-)
33H (3)
32H (2)
34H (4)
35H (5)
0000H
-
1
2
3
4
5
BIN16
Summary of Contents for MELSEC iQ-F FX5
Page 1: ...MELSEC iQ F FX5 Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 17: ...15 CONTENTS ...
Page 24: ...22 MEMO ...
Page 1050: ...1048 26 TIME DATA FUNCTIONS 26 4 Division MEMO ...
Page 1068: ...1066 29 COUNTER FUNCTION BLOCKS 29 4 Counter Function Block Operation error There is no error ...
Page 1107: ...I 1105 MEMO ...
Page 1111: ......