This manual confers no industrial property rights or any rights of any other kind, 
nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be 
held responsible for any problems involving industrial property rights which may 
occur as a result of using the contents noted in this manual.

Warranty

Mitsubishi will not be held liable for damage caused by factors found not to be 
the cause of Mitsubishi; opportunity loss or lost profits caused by faults in the 
Mitsubishi products; damage, secondary damage, accident compensation 
caused by special factors unpredictable by Mitsubishi; damages to products 
other than Mitsubishi products; and to other duties.

For safe use

This product has been manufactured as a general-purpose part for general 
industries, and has not been designed or manufactured to be incorporated in 
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric 
power, aerospace, medicine or passenger movement vehicles, consult with 
Mitsubishi Electric.
This product has been manufactured under strict quality control. However 
when installing the product where major accidents or losses could occur if the 
product fails, install appropriate backup or failsafe functions in the system.

HEAD OFFICE  : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

Safety Precaution

 

(Read these precautions before use.)

This manual classify the safety precautions into two categories: 

 and 

.

Depending on circumstances, procedures indicated by 

 may also be

linked to serious results.
In any case, it is important to follow the directions for usage.

Associated Manuals

Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.

Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.

Manual name

Manual No.

Description

FX

3S

 Series User’s Manual

- Hardware Edition

JY997D48601

MODEL CODE: 

09R535

Explains FX

3S

 Series PLC

specification details for I/O,

w i r i n g ,   i n s t a l l a t i o n ,   a n d

maintenance.

FX

3G

 Series User’s Manual

- Hardware Edition

JY997D31301

MODEL CODE: 

09R521

Explains FX

3G

 Series PLC

specification details for I/O,

w i r i n g ,   i n s t a l l a t i o n ,   a n d

maintenance.

FX

3GC

 Series User’s Manual

- Hardware Edition

JY997D45401

MODEL CODE:

09R533

Explains FX

3GC

 Series PLC

specification details for I/O,

w i r i n g ,   i n s t a l l a t i o n ,   a n d

maintenance.

FX

3U

 Series User’s Manual 

- Hardware Edition

JY997D16501

MODEL CODE: 

09R516

Explains FX

3U

 Series PLC

specification details for I/O,

w i r i n g ,   i n s t a l l a t i o n ,   a n d

maintenance.

FX

3UC

 Series User’s Manual 

- Hardware Edition

JY997D28701

MODEL CODE: 

09R519

Explains FX

3UC

 Series PLC

specification details for I/O,

w i r i n g ,   i n s t a l l a t i o n ,   a n d

maintenance.

FX

3S

/FX

3G

/FX

3GC

/FX

3U

/

FX

3UC

 Series 

Programming Manual 
- Basic & Applied Instruction 
Edition

JY997D16601

MODEL CODE: 

09R517

Describes PLC programming

for basic/applied instructions

and devices.

FX Series User’s Manual 
- Data Communication Edition

JY997D16901

MODEL CODE: 

09R715

Explains N:N link, parallel link, 

computer link, no protocol 

communication by RS 

instructions/FX

2N

-232IF.

How to obtain manuals

For the necessary product manuals or documents, consult with the Mitsubishi Electric
dealer from where you purchase your product.

Applicable standards

FX

3U

-232ADP-MB  units made in April, 2007 or later comply with the EC Directive

(EMC Directive) and UL standards (UL, cUL). Further information can be found in the
following manual.



FX

3S

 Series Hardware Manual (Manual No. JY997D48301)



FX

3G

 Series Hardware Manual (Manual No. JY997D46001)



FX

3GC

 Series Hardware Manual (Manual No. JY997D45201)



FX

3U

 Series Hardware Manual (Manual No. JY997D18801)



FX

3UC

 (D, DS, DSS) Series Hardware Manual (Manual No. JY997D28601)



FX

3UC

-32MT-LT-2 Hardware Manual (Manual No. JY997D31601)

Regarding the standards that relate to the main unit, please refer to either the FX
series product catalog or consult with your nearest Mitsubishi product provider.

Attention

This product is designed for use in industrial applications.

Note

Authorized Representative in the European Community:

Mitsubishi Electric Europe B.V.
Gothaer Str. 8, 40880 Ratingen, Germany

1. Outline

The FX

3U

-232ADP-MB communication special adapter (hereinafter called 232ADP-

MB) is a special adapter for RS-232C communication with an 9-pin D-Sub connector.
232ADP-MB is an isolated signal exchange unit of the RS-232C serial data
communication between the PLC and RS-232C device.
The FX

3U

-232ADP-MB features all functionality that is available with the FX

3U

-

232ADP, except that it also has MODBUS communication available.

1.1 Communication Function

1.2 Incorporated Items

Verify that the following product and items are included in the package:

Manual name

Manual No.

Description

FX

3S

/FX

3G

/FX

3GC

/FX

3U

/

FX

3UC

 Series User’s Manual

- MODBUS Serial 
Communication Edition

JY997D26201

Explains the MODBUS serial 

communication network.

Communication type

Function

Computer link

Data transfer via dedicated protocol between PLC and
computer (specified as the master station).

Non-protocol 
communication

Serial communication via non-protocol between PLC and
RS-232C device.

Programming 
communication

Optional port available for suitable programming tool when
232ADP-MB is connected to PLC.

Remote maintenance

Program transfer or monitoring enabled via modem and
phone line connected to serial port of PLC.

MODBUS 
communication

Data transfer between a master and a slave.

Product

FX

3U

-232ADP-MB communication special adapter

Accessories

Installation manual (This manual)

1.3 External Dimensions and Part Names 

1.4 Pin Configuration

The pin configuration of the RS-232C port on the 232ADP-MB is as shown below.

[1] DIN rail mounting groove (DIN rail: DIN46277)
[2] Name plate
[3] Special adapter slide lock: 

Used to connect special adapter on left side of this special adapter.

[4] Special adapter connector cover:

Remove this cover for connecting special adapter on the left side.

[5] Direct mounting hole:2 holes of 

4.5 (0.18") (mounting screw: M4 screw)

Not used when connecting to FX

3GC

/FX

3UC

 Series PLC.

[6] POWER LED (green): Lit while 5 V DC power is supplied from main unit.
[7] RD LED (red): 

Lit while receiving data from connected RS-232C device.

[8] SD LED (red): 

Lit while sending data to connected RS-232C device.

[9] Special adapter connector:

Used to connect this special adapter to PLC main unit or special adapter.

[10] RS-232C connector (9-pin D-Sub, male): 

Connect RS-232C device to this RS-232C connector

[11] Screws to fix a cable connector: Screw holes #4-40UNC (inch screw thread)
[12] DIN rail mounting hook
[13] Special adapter fixing hook
[14] Special adapter connector:

Used to connect communication special adapter or analog special adapter to
this adapter on left side.

Pin 
No.

Signal

Name

Function

1

CD
(DCD)

Receive 
carrier 
detection

ON when carrier for data reception 
is detected. 
(RS-232C device to 232ADP-MB)

2

RD
(RXD)

Receive 
data

Receive data
(RS-232C device to 232ADP-MB)

3

SD
(TXD)

Send data

Send data
(232ADP-MB to RS-232C device)

4

ER
(DTR)

Send 
request 

ON when RS-232C device is ready 
to receive data. 
(232ADP-MB to RS-232C device)

5

SG
(GND)

Signal 
ground

Signal ground
(232ADP-MB to RS-232C device)

6

DR
(DSR)

Send 
enable 

ON when send request is made 
toward RS-232C device.
(RS-232C device to 232ADP-MB)

7,8,9 Not used

[3]

[6]

[5]

[7]
[8]

[9]

[10]

[11]

[12]

[14]

[13]

[2]

[4]

[1]

74(2.92")

Weight: Approx. 80 g (0.18 lbs)

Special adapter 

connector cover 

is removed  

7(0.28")

90(3.55")

98(3.86")

(mounting hole pitch)

106(4.18")

17.6

(0.7")

7.5
(0.29")

15.1

(0.6")

Screws to fix

RS-232C

connector

1

5

6

9

Screw holes:

#4-40UNC

(inch screw

thread)

2. Channel Allocation

Up to two communication ports can be added to the main unit.
Refer to the following manual for equipment that occupies communication ports.



FX Series User’s Manual - Data Communication Edition

FX

3S

 Series PLC

Communication port channels are automatically allocated.

FX

3G

 

Series PLC

Communication port channels are automatically allocated.

40-point, 60-point type

14-point, 24-point type

FX

3GC

 Series PLC

Communication port channels are automatically allocated. The communication
special adapter closer to the main unit is ch1.

FX

3U

/FX

3UC

-32MT-LT(-2) Series PLC

Communication port channels are automatically allocated. The communication
special adapter closer to the main unit is ch1.

Using one communication special a communication expansion board

Using two communication special adapters

     Main unit

(ch1)

FX

3U

-

232ADP

-MB

Analog

special

adapter

FX

3S

-

CNV-ADP

     Main unit

(ch1)

(ch2)

Analog

special

adapter

Analog

special

adapter

FX

3U

-

232ADP

-MB

FX

3U

-

232ADP

-MB

FX

3G

-

CNV-ADP

Main unit

(ch1)

Communication

expansion board (ch2)

Analog

special

adapter

FX

3U

-

232ADP

-MB

Analog

special

adapter

FX

3G

-

CNV-ADP

     Main unit

(ch1)

FX

3U

-

232ADP

-MB

Analog

special

adapter

FX

3G

-

CNV-ADP

Main unit

(ch1)

(ch2)

Analog

special

adapter

Analog

special

adapter

FX

3U

-

232ADP

-MB

FX

3U

-

232ADP

-MB

Analog

special

adapter

Analog

special

adapter

Analog

special

adapter

Analog

special

adapter

FX

3U

-

232ADP

-MB

     Main unit

Communication

expansion board (ch1)

(ch2)

Analog

special

adapter

Analog

special

adapter

Analog

special

adapter

FX

3U

-

232ADP

-MB

Analog

special

adapter

FX

3U

-

232ADP

-MB

     Main unit

FX

3U

-CNV-BD

(ch1)

(ch2)

FX

3UC

 (D, DS, DSS) Series PLC

Communication port channels are automatically allocated. The communication
special adapter closer to the main unit is ch1.

3. Installation

For installation/uninstallation details, refer to the respective PLC User's manual
Hardware Edition.

  

3.1 Connection to the PLC

This section describes the connection method to the PLC (FX

3U

 Series PLC is

used for the following example).

For installation method to other PLCs, refer to the respective PLC User's manual
Hardware Edition.

Procedure

1) Turn off the power.

Disconnect all the cables connected to the PLC main unit and special adapter. 

Dismount the main unit and special adapter mounted on DIN rail or mounted

directly using screws. 

2) Install an expansion board to the main unit.

For installation of expansion board, refer to the following manual:



FX

3U

 Series User's Manual - Hardware Edition

3) Remove the special adapter connector cover

on the expansion board (Right fig.A).
In case of connecting this product to another
special adapter, please replace the
'expansion board' in the above description
with a 'special adapter' and perform the
procedure as indicated.

4) Slide the special adapter slide lock (Right

fig.B) of the main unit.
In case of connecting this product to another
special adapter, please replace the 'main
unit' in the above description with a 'special
adapter' and perform the procedure as
indicated. (Please replace the following
procedures similarly.)

5) Connect the 

special adapter 
(Right fig.C) to 
the main unit as 
shown on the 
right.

6) Slide back the 

special adapter 
slide lock (Right 
fig.B) of the main 
unit to fix the 
special adapter 
(Right fig.C). 

Connection precautions

Connect all the high-speed I/O special adapters before connecting other
special adapters when they are used in combination.

Do not connect a high-speed I/O special adapter on the left side of a
communication or analog special adapter.

INSTALLATION 
PRECAUTIONS

Make sure to cut off all phases of the power supply externally before
attempting installation or wiring work.
Failure to do so may cause electric shock or damage to the product.

INSTALLATION 
PRECAUTIONS

Use the product within the generic environment specifications described in
PLC main unit manual (Hardware Edition).
Never use the product in areas with excessive dust, oily smoke, conductive
dusts, corrosive gas (salt air, Cl

2

, H

2

S, SO

2

, or NO

2

), flammable gas, vibration 

or impacts, or expose it to high temperature, condensation, or rain and wind.
If the product is used in such conditions, electric shock, fire, malfunctions,
deterioration or damage may occur.

When drilling screw holes or wiring, make sure cutting or wire debris does not
enter the ventilation slits. 
Failure to do so may cause fire, equipment failures or malfunctions.

Do not touch the conductive parts of the product directly.
Doing so may cause device failures or malfunctions.

Connect special adapter securely to their designated connectors.
Loose connections may cause malfunctions.

Main unit

(ch1)

(ch2)

Analog

special

adapter

Analog

special

adapter

Analog

special

adapter

Analog

special

adapter

FX

3U

-

232ADP

-MB

FX

3U

-

232ADP

-MB

RUN

STOP

FX

FX

3U

3U-48MR/ES

-48

MR

/ES

FX

3U-48M

3)

4)

B

B

A

4)

RUN

STOP

FX

FX

3U

3U-48MR/ES

-48

MR

/ES

FX

FX

3U

3U

-48M

-48M

POWER

RD

SD

FX

3U

-232ADP

-MB

FX

3U-48M

6)

C

B

B

5)

5)

5)

6)

4. Wiring

For wiring details, refer to the following manual.



FX

 

Series User's Manual - Data Communication Edition



FX

3S

/FX

3G

/FX

3GC

/FX

3U

/FX

3UC

 Series User’s Manual

- MODBUS Serial Communication Edition

5. Specification 

 

5.1 Applicable PLC

The version number can be checked by monitoring D8001/D8101, as well the last three
digits indicate the version number.

5.2 General Specifications

Items other than the following are equivalent to the those of the PLC main unit.
For general specifications, refer to the respective PLC User's manual Hardware Edition.

5.3 Power Supply Specification

WIRING 
PRECAUTIONS

Make sure to cut off all phases of the power supply externally before attempting
installation or wiring work.
Failure to do so may cause electric shock or damage to the product.

WIRING 
PRECAUTIONS

When drilling screw holes or wiring, make sure cutting or wire debris does not
enter the ventilation slits. 
Failure to do so may cause fire, equipment failures or malfunctions.

Make sure to observe the following precautions in order to prevent any damage to
the machinery or accidents due to abnormal data written to the PLC under the
influence of noise:

- Do not bundle the main circuit line together with or lay it close to the main 

circuit, high-voltage line or load line. 
Otherwise, noise disturbance and/or surge induction are likely to take place. 
As a guideline, lay the control line at least 100mm (3.94") or more away from 
the main circuit or high-voltage lines.

STARTUP AND 
MAINTENANCE 
PRECAUTIONS

Do not disassemble or modify the unit.
Doing so may cause fire, equipment failures, or malfunctions. 
* For repair, contact your local Mitsubishi Electric representative.

Do not drop the product or exert strong impact to it.
Doing so may cause damage.

DISPOSAL 
PRECAUTIONS

Please contact a certified electronic waste disposal company for the
environmentally safe recycling and disposal of your device.

TRANSPORTATION AND 
STORAGE PRECAUTIONS

The product is a precision instrument. During transportation, avoid any impacts.
Failure to do so may cause failures in the product. After transportation, verify the
operations of the product.

Model name

Applicability

FX

3S

 Series PLC

Ver. 1.00 or later for all communication functions

FX

3G

 Series PLC

Ver. 1.30 or later for MODBUS communication
Ver. 1.00 or later for all communication functions except 
MODBUS

FX

3GC

 Series PLC

Ver. 1.40 or later for all communication functions

FX

3U

 Series PLC

Ver. 2.40 or later for MODBUS communication
Ver. 2.20 or later for all communication functions except 
MODBUS

FX

3UC

 Series PLC

Ver. 2.40 or later for MODBUS communication
Ver. 1.00 or later for all communication functions except 
MODBUS

Item

Specification

Dielectric withstand 
voltage

500 V AC, one minute

Between terminal block and
ground terminal of PLC main unit

Insulation resistance

5 M

 or more by 500 V

DC megger 

Item

Specification

Current consumption

30 mA
5 V DC power is supplied internally from the main unit.

5.4 Performance Specification

*1 Applicable for FX

3U

/FX

3UC

 Series PLC Ver. 2.41 or later and FX

3S

/FX

3G

/FX

3GC

Series PLC.

*2 When you set the baud rate to 38400 bps or more in a FX

3S

/FX

3G

/FX

3GC

 Series

PLC, please set D8411 (D8431) to be 3 ms or more. When D8411 (D8431) is set
at less than 3 ms, it may not be able to communicate normally.

*3 Applicable for products manufactured in July, 2012 or later (manufacturer's serial

number: 127**** or later). The year and month of production of the special
adapter can be checked from the manufacturer's serial number "S/N" indicated
on the label.
For manufacturer's serial number, refer to the following manual.



FX

3S

/FX

3G

/FX

3GC

/FX

3U

/FX

3UC

 SERIES USER'S MANUAL

- MODBUS Serial Communication Edition

Item

Specification

Transmission 
standard

Conforming to RS-232C

Type of isolation

Photocoupler isolation

Transmission 
distance

15 m (49’ 2") or less

Connection method

9-pin D-Sub connector (male)

Number of occupied I/
O points

0 point (This number is not related to the maximum number
of input/output points of the PLC.) 

Communication 
method

Full-duplex

Baud rate

Computer link, and Non-protocol Items other than the
following are equivalent to the those of the PLC main unit.
For general specifications, refer to the respective PLC
User's manual Hardware Edition.: 

300/600/1200/2400/4800/9600/19200/38400

*1

 bps

Programming communication:

9600/19200/38400/57600/115200 bps

Remote maintenance: 9600 bps
MODBUS communication

*2

:

300/600/1200/2400/4800/9600/19200/38400

*3

/57600

*3

/

115200

*3

 bps

Communication 
format

Computer link (dedicated protocol: format 1/format 4), 
Non-protocol, Programming communication, Remote
maintenance, and MODBUS communication

LED display: 
LED color

Power: green, RD: red, SD: red

Side

A

Side

B

JAPANESE

ENGLISH

JY997D26401F

Side

B

FX

3U

-232ADP-MB

Installation Manual

This manual describes the part names, dimensions, mounting, and specifications
of the product. Before use, read this manual and manuals of relevant products
fully to acquire proficiency in handling and operating the product. Make sure to
learn all the product information, safety information, and precautions.
And, store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user.
Registration:
MODBUS

 is a registered trademark of Schneider Electric S.A.

The company name and the product name to be described in this manual are the
registered trademarks or trademarks of each company.

Effective April 2015
Specifications are subject to change without notice.

 2007 Mitsubishi Electric Corporation

Manual Number

JY997D26401

Revision

F

Date

April 2015

Summary of Contents for MELSEC FX3U-232ADP-MB

Page 1: ...コネクタ D SUB 9Pin オス 232ADP MBとRS 232C機器との接続に使用します 11 ケーブルコネクタ固定用ネジ ネジ穴 4 40UNC インチネジ 12 DINレール取付用フック 13 特殊アダプタ連結用ツメ 14 特殊アダプタ接続用コネクタ 本特殊アダプタの左側に通信特殊アダプタまたはアナログ特殊アダプタを接続す るときに使用します 1 4 コネクタPin配列 232ADP MBのRS 232C通信用コネクタのPin配列は次のようになります ピン 番号 信号 名称 機能 1 CD DCD 受信キャリア 検出 データ受信のためのキャリ アが検出されたときON RS 232C機器 232ADP MB 2 RD RXD 受信データ 入力 受信データ RS 232C機器 232ADP MB 3 SD TXD 送信データ 出力 送信データ 232ADP MB RS 232C機器...

Page 2: ...さい ほこり 油煙 導電性ダスト 腐食性ガス 潮風 Cl2 H2S SO2 NO2など 可燃性ガスのある場所 高温 結露 風雨にさらされる場所 振動 衝撃がある 場所で使用しないでください 感電 火災 誤動作 製品の損傷および劣化の原因となることがあります ネジ穴加工や配線工事を行うときに 切粉や電線屑をシーケンサの通風窓へ 落とし込まないでください 火災 故障 誤動作の原因となります 製品の導電部には直接触らないでください 誤動作 故障の原因となります 特殊アダプタは所定のコネクタに確実に装着してください 接触不良により誤動作の原因となることがあります 通信機能拡張ボード ch1 ch2 アナログ 特殊 アダプタ アナログ 特殊 アダプタ アナログ 特殊 アダプタ アナログ 特殊 アダプタ FX3U 232ADP MB 基本 ユニット ch1 ch2 アナログ 特殊 アダプタ アナログ ...

Page 3: ...機能 1 CD DCD 受信キャリア 検出 データ受信のためのキャリ アが検出されたときON RS 232C機器 232ADP MB 2 RD RXD 受信データ 入力 受信データ RS 232C機器 232ADP MB 3 SD TXD 送信データ 出力 送信データ 232ADP MB RS 232C機器 4 ER DTR 送信要求 RS 232C 機器が受信可能な 状態でON 232ADP MB RS 232C機器 5 SG GND 信号グランド 信号グランド 6 DR DSR 送信可 RS 232C機器に対して送信要 求をするとON RS 232C機器 232ADP MB 7 8 9 使用しません 質量 約80g 外装色 マンセル0 08GY 7 64 0 81 DINレール幅 35mm 取付穴ピッチ 1 5 6 9 RS 232C コネクタ 固定用 ネジ ネジ穴 4 40UNC イ...

Page 4: ...55 98 3 86 mounting hole pitch 106 4 18 17 6 0 7 7 5 0 29 15 1 0 6 Screws to fix RS 232C connector 1 5 6 9 Screw holes 4 40UNC inch screw thread 2 Channel Allocation Up to two communication ports can be added to the main unit Refer to the following manual for equipment that occupies communication ports FX Series User s Manual Data Communication Edition FX3S Series PLC Communication port channels a...

Page 5: ... adapter and perform the procedure as indicated Please replace the following procedures similarly 5 Connect the special adapter Right fig C to the main unit as shown on the right 6 Slide back the special adapter slide lock Right fig B of the main unit to fix the special adapter Right fig C Connection precautions Connect all the high speed I O special adapters before connecting other special adapte...

Page 6: ...ter Analog special adapter FX3U 232ADP MB Main unit Communication expansion board ch1 ch2 Analog special adapter Analog special adapter Analog special adapter FX3U 232ADP MB Analog special adapter FX3U 232ADP MB Main unit FX3U CNV BD ch1 ch2 FX3UC D DS DSS Series PLC Communication port channels are automatically allocated The communication special adapter closer to the main unit is ch1 3 Installat...

Reviews: