background image

)

p

3-1. PURGING PROCEDURES AND LEAK TEST

Refer to the procedures indicated in the installation manual of the outdoor unit.

3-3. AUTO RESTART FUNCTION

This product is equipped with an auto restart function. When the power supply is stopped 
during operation, such as during blackouts, the function automatically starts operation in 
the previous setting once the power supply is resumed. (Refer to the operating instruc-
tions for details.) 

3-4. EXPLANATION TO THE USER

•  Using the OPERATING INSTRUCTIONS, explain to the user how to use the air condi-

tioner (how to use the remote controller, how to remove the air filters, how to remove 
or put the remote controller in the remote controller holder, how to clean, precautions 
for operation, etc.).

•  Recommend the user to read the OPERATING INSTRUCTIONS carefully.

4-1. REMOVING AND INSTALLING THE PANEL ASSEMBLY

4-3. PUMPING DOWN

When relocating or disposing of the air conditioner, pump down the system following the 
procedure below so that no refrigerant is released into the atmosphere.
1) Connect the gauge manifold valve to the service port of the stop valve on the gas pipe 

side of the outdoor unit.

2) Fully close the stop valve on the liquid pipe side of the outdoor unit.
3) Close the stop valve on the gas pipe side of the outdoor unit almost completely so that 

it can be easily closed fully when the pressure gauge shows 0 MPa [Gauge] (0 kgf/
cm

2

).

4) Start the emergency COOL operation.
  To start the emergency operation in COOL mode, disconnect the power supply plug 

and/or turn off the breaker. After 15 seconds, connect the power supply plug and/or 
turn on the breaker, and then press the E.O. SW once. (The emergency COOL 
operation can be performed continuously for up to 30 minutes.)

5) Fully close the stop valve on the gas pipe side of the outdoor unit when the pressure 

gauge shows 0.05 to 0 MPa [Gauge] (approx. 0.5 to 0 kgf/cm

2

).

6) Stop the emergency COOL operation.
  Press the E.O. SW several times until all LED lamps turn off. Refer to operating in-

structions for details.

4-2. REMOVING THE INDOOR UNIT

Remove the bottom of the indoor unit from the installation 
plate.
When releasing the corner part, release both left and right 
bottom corner part of indoor unit and pull it downward and 
forward as shown in the figure on the right.

Removal procedure

1) Unlock the upper and lower vanes as 

shown in 

 and 

 using a thin instrument. 

Then, remove the horizontal vanes.

2) Remove the 2 screws which fix the panel 

assembly.

3) Remove the panel assembly. Be sure to 

remove its bottom right end first.

Installation procedure

1) Install the panel assembly following the removal 

procedure in reverse. 

2) Be sure to press the positions as indicated by the 

arrows in order to attach the assembly completely to 
the unit.

3) Install the horizontal vanes.

Caution:

•  After test run or remote signal reception check, turn off the unit with the E.O. SW or 

the remote controller before turning off the power supply. Not doing so will cause the 
unit to start operation automatically when power supply is resumed.

To the user

•  After installing the unit, make sure to explain the user about auto restart function. 
•  If auto restart function is unnecessary, it can be deactivated. Consult the service 

representative to deactivate the function. Refer to the service manual for details.

3.  PURGING PROCEDURES, LEAK TEST, AND TEST RUN

4. RELOCATION AND MAINTENANCE

3

3

3

3

When pumping down the refrigerant, stop the compressor before disconnecting 
the refrigerant pipes. The compressor may burst if air etc. get into it.

 

WARNING

Unlock

Upper and 
lower vanes

3-2. TEST RUN

1) Insert power supply plug into the power outlet and/or turn on 

the breaker.

2) Press the E.O. SW once for COOL, and twice for HEAT 

operation. Test run will be performed for 30 minutes. If the 
left lamp of the operation indicator blinks every 0.5 seconds, 
inspect the indoor/outdoor unit connecting wire (A) for mis-
wiring. After the test run, emergency mode (set temperature 
24°C) will start.

3) To stop operation, press the E.O. SW several times until all 

LED lamps turn off. Refer to operating instructions for details. 

Checking the remote (infrared) signal reception

Press the ON/OFF button on the remote controller (6) and check that an electronic sound 
is heard from the indoor unit. Press the ON/OFF button again to turn the air conditioner off.
•  Once the compressor stops, the restart preventive device operates so the compressor 

will not operate for 3 minutes to protect the air conditioner.

Emergency  
operation switch
(E.O. SW)

HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 
100-8310, JAPAN

Summary of Contents for JG79R296H01

Page 1: ...rm the installation securely referring to the installation manual Incomplete installation could cause fire electric shock or injury due to the unit falling or leakage of water N When installing the unit use appropriate protective equipment and tools for safety Failure to do so could cause injury N Install the unit securely in a place which can bear the weight of the unit If the installation locatio...

Page 2: ...o prevent damage by rodents in case the wall is hollow Wall hole cover D Seal the wall hole gap with putty H Fix the pipe to wall with pipe fixing band E Fixing screw F After the leak test apply insulating material tightly so that there is no gap When the piping is to be at tached to a wall containing metals tin plated or metal netting use a chemically treated wooden piece 20 mm or thicker between ...

Page 3: ... then tighten the first 3 to 4 turns of flare nut Use tightening torque table above as a guideline for indoor unit side union joint section and tighten using two wrenches Excessive tightening damages the flare section Outdoor unit connection Connect pipes to stop valve pipe joint of the outdoor unit in the same manner applied for indoor unit For tightening use a torque wrench or spanner and use the s...

Page 4: ...ner part of indoor unit and pull it downward and forward as shown in the figure on the right Removal procedure 1 Unlock the upper and lower vanes as shown in and using a thin instrument Then remove the horizontal vanes 2 Remove the 2 screws which fix the panel assembly 3 Remove the panel assembly Be sure to remove its bottom right end first Installation procedure 1 Install the panel assembly followin...

Reviews: