19. ENERGY MEASURING UNIT/ELECTRIC MULTI-MEASURING INSTRUMENT CONNECTION
19.3 Connection Diagram
19 - 7
17
ROBOT
CONT
ROLLER
CONN
E
C
T
ION
18
CNC CONNECTION
19
ENER
GY M
EASU
RIN
G
UNIT/ELEC
TRIC M
UL
TI
-
MEA
S
UR
IN
G IN
STRUM
EN
T
CON
NEC
TION
20
GOT
MUL
T
I-
DROP
CONNECTION
21
M
U
LT
IP
LE
-G
T1
4,
GT
12
,
GT
11
, G
T10
CO
NNEC
TIO
N FUNCTION
22
MUL
T
I-CHANNE
L
FUNC
TION
23
F
A
TRANSP
A
R
ENT
FUNCT
ION
RS-422/485 connection diagram 6)
*1
The signal name differs depending on the series name. Refer to the following table.
*2
Short-circuit between the following terminals of the energy measuring unit or electric multi-measuring instrument which will be a
terminal.
By the short circuit of the following terminals, a terminating resistor with 120 is connected.
*3
When placing the GOT to the terminal, set the terminating resistor of the GOT to "Enable".
When placing the GOT to the position other than the terminal, set the terminating resistor of the GOT to "Disable".
1.4.3 Terminating resistors of GOT
*4
Ground a shield correctly.
RS-422/485 connection diagram 7)
*1
The signal name differs depending on the series name. Refer to the following table.
*2
Short-circuit between the following terminals of the energy measuring unit or electric multi-measuring instrument which will be a
terminal.
By the short circuit of the following terminals, a terminating resistor with 120 is connected.
*3
Set the 2-wire/4-wire terminating resistor setting switch of the RS-232/485 signal conversion adaptor as follows.
2-wire type/4-wire type: 2-wire type (1Pair)
When placing the GOT to the terminal: Set the terminating resistor of the GOT to "110 ".
When placing the GOT to the position other than the terminal: Set the terminating resistor of the GOT to "OPEN".
1.4.4 Setting the RS-232/485 signal conversion adaptor
*4
For the RS232 setting, check "Enable the 5V power supply".
1.1.2 I/F communication setting
*5
Ground a shield correctly.
Series name
Signal name 1)
Signal name 2)
Energy measuring unit
RS485+
RS485-
Electric multi-measuring instrument
T/R+
T/R-
Series name
Signal name
Signal name
Energy measuring unit
RS485-
< - >
Ter
Electric multi-measuring instrument
T/R-
< - >
Ter
GOT side(Terminal block)
*3
SDA1
SDB1
RDA1
RDB1
SDA2
SDB2
RDA2
RDB2
SG
FG
1
2
3
4
5
6
7
8
9
10
Signal name
1)
*1
2)
*1
Ter
SLD
*2
Signal name
1)
*1
2)
*1
Ter
SLD
ENERGY MEASURING UNIT
ELECTRIC MULTI-MEASURING
INSTRUMENT (1st)
ENERGY MEASURING UNIT
ELECTRIC MULTI-MEASURING
INSTRUMENT (1st)
*4
*4
Series name
Signal name 1)
Signal name 2)
Energy measuring unit
RS485+
RS485-
Electric multi-measuring instrument
T/R+
T/R-
Series name
Signal name
Signal name
Energy measuring unit
RS485-
< - >
Ter
Electric multi-measuring instrument
T/R-
< - >
Ter
SDA
SDB
RDA
RDB
SG
Signal name
1)
*1
2)
*1
Ter
SLD
*2
Signal name
1)
*1
2)
*1
Ter
SLD
GOT side
(Terminal block)
*3*4
ENERGY MEASURING UNIT
ELECTRIC MULTI-MEASURING
INSTRUMENT (1st)
ENERGY MEASURING UNIT
ELECTRIC MULTI-MEASURING
INSTRUMENT (1st)
*4
*4
Summary of Contents for GT15
Page 2: ......
Page 34: ...A 32 ...
Page 92: ......
Page 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Page 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Page 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Page 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Page 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Page 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Page 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Page 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Page 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Page 510: ......
Page 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Page 668: ......
Page 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Page 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Page 714: ......
Page 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Page 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Page 762: ......
Page 860: ...REVISIONS 4 ...
Page 863: ......