11. CC-Link IE CONTROLLER NETWORK CONNECTION
11.2 System Configuration
11.2 System Configuration
11.2.1 Connecting to optical loop system
*1
When the CC-Link IE Controller Network is in the extended mode, use a unit with the upper five digits of the serial No. 12052 or
later.
For the system configuration on the CC-Link IE Controller Network module side, refer to the following manual.
CC-Link IE Controller Network Reference Manual
*2
For the optical fiber cable, refer to the following manual.
CC-Link IE Controller Network Reference Manual
*3
The overall extension cable length and the length between stations vary depending on the cable type to be used and the total
number of stations.
For details, refer to the following manual.
CC-Link IE Controller Network Reference Manual
*4
When Universal model QCPUs is a control station, up to 119 GOTs can be connected.
When a QCPU other than Universal model QCPU is the control station, the number of connectable GOTs is 63 units (at most).
Basic model QCPU and the QSCPU cannot be used as the control station.
*5
When the CC-Link IE Controller Network is in the extended mode, only MELSEC-Q series Universal model QCPU can be used.
*6
When the CC-Link IE Controller Network is in the extended mode, use a module with the serial No. 02910908******* or later.
CC-Link IE controller
network module
PLC CPU
GOT
Connection cable
CC-Link IE Controller Network
Communication driver
PLC
Connection cable
GOT
Number of
connectable
equipment
Model name
*5
CC-Link IE controller
network
communication unit*1
Communication
type
Cable model
Max.
distance
Option device
Model
MELSEC iQ-R
Series
Motion controller
CPU (MELSEC
iQ-R Series)
C Controller
module
(MELSEC iQ-R
Series)
RJ71GP21-SX
CC-Link IE
Optical fiber cable
*2
*3
GT15-J71GP23-SX
*6
119 GOTs
*4
MELSEC-Q
C Controller
module
(Q Series)
MELSEC-QS
QJ71GP21-SX
QJ71GP21S-SX
CC-Link IE
Optical fiber cable
*2
*3
GT15-J71GP23-SX
*6
119 GOTs
*4
Summary of Contents for GT15
Page 2: ......
Page 34: ...A 32 ...
Page 92: ......
Page 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Page 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Page 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Page 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Page 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Page 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Page 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Page 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Page 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Page 510: ......
Page 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Page 668: ......
Page 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Page 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Page 714: ......
Page 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Page 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Page 762: ......
Page 860: ...REVISIONS 4 ...
Page 863: ......