2 - 12
2. DEVICE RANGE THAT CAN BE SET
2.5 MELSEC-QnA/Q/QS, MELDAS C6 *
2.5 MELSEC-QnA/Q/QS, MELDAS C6 *
The device ranges that can be set when selecting
[MELSEC-QnA/Q/QS, MELDAS C6*]
*12
as the controller
type are as follows.
*1
Do not set a file register by GT Designer3 when executing
multiple programs with the file of the file register set at [Use
the same file name as the program] by the PLC parameter of
GX Developer.(Except MELSEC-QnA)
Otherwise, read/write at GOT will be erroneous.
*2
Available for file register of block No. switched with the RSET
instruction.
*3
Available for file register of block No. of file name switched
with the QDRSET instruction.
*4
Only the intelligent function module on the station connected
to GOT can be specified.
Set within the address range of the buffer memory existing in
the target intelligent function module.
*5
The device No. must be set in multiples of 16.
*6
When monitoring MELDAS C6/64, if a word device outside
the range is set, the value becomes indefinite.
When a bit device outside the range is set, the object may
not be displayed or the set function may fail to operate.
Check the set device using the device list of GT Designer3.
*7
Devices used by the MELDAS C6/64 system cannot be
used.
*8
Do not use local devices set in the MELSEC-Q system.
Otherwise, normal monitoring is not performed.
*9
This is not supported by GT10.
*10
This cannot be monitored when in GOT multi-drop
connection.
*11
Only reading is possible from QS001CPU.
*12
For GT14, GT11 and GT10, the controller type is as follows.
• GT14, GT11: MELSEC-QnA/Q, MELDAS C6 *
• GT10: MELSEC-QnA/Q
Device name
*6*7*11
Setting range
Device No.
representation
B
it device
Input (X)
X0
to
X3FFF
Hexadecimal
Output (Y)
Y0
to
Y3FFF
Internal relay (M)
*8
M0
to
M32767
Decimal
Latch relay (L)
L0
to
L32767
Annunciator (F)
F0
to
F32767
Link relay (B)
B0
to
B7FFF
Hexadecimal
Timer
*8
Contact (TT)
TT0
to
TT32767
Decimal
Coil (TC)
TC0
to
TC32767
Counter
*8
Contact (CT)
CT0
to
CT32767
Coil (CC)
CC0
to
CC32767
Special relay (SM)
SM0
to
SM2047
Retentive
timer
*8
Contact (SS)
SS0
to
SS32767
Coil (SC)
SC0
to
SC32767
Step relay (S)
S0
to
S32767
Link special relay (SB)
SB0
to
SB7FFF
Hexadecimal
The bit specification of the
word device
(except Timer, Counter,
Retentive timer, Index
register)
Setting range of each
word device
―
W
ord device
Data register (D)
*8
D0
to
D32767
Decimal
Special data register (SD)
SD0
to
SD2047
Link register (W)
W0
to
W7FFF
Hexadecimal
Timer (current value) (TN)
*8
TN0
to
TN32767
Decimal
Counter (current value)
(CN)
*8
CN0
to
CN32767
Retentive timer
(current value) (SN)
*8
SN0
to
SN32767
Link special register (SW)
SW0 to
SW7FFF
Hexadecimal
File register (R)
*1*2
R0
to
R32767
Decimal
Extension
file register
(ER)
*1*9*10
Block
0
to
255
Device
R0
to
R32767
Extension file register
(ZR)
*1*3*9*10
ZR0
to
ZR1042431
Index register (Z)
Z0
to
Z15
Buffer memory
(Intelligent function module)
(BM)
*4*9*10
BM0
to
BM32767
Buffer memory
(Intelligent function module)
(G)
*4*9*10
G0
to
G65535
Ww
*9*10
Ww0 to
Ww1FFF
Hexadecimal
Wr
*9*10
Wr0
to
Wr1FFF
The word specification of
the bit device
*5*9
(except Timer, Counter,
Retentive timer)
Setting range of each bit
devices
―
Summary of Contents for GT15
Page 2: ......
Page 34: ...A 32 ...
Page 92: ......
Page 110: ...2 18 2 DEVICE RANGE THAT CAN BE SET 2 9 MELSEC WS ...
Page 186: ...5 10 5 BUS CONNECTION 5 2 System Configuration ...
Page 218: ...5 42 5 BUS CONNECTION 5 4 Precautions ...
Page 254: ...6 36 6 DIRECT CONNECTION TO CPU 6 6 Precautions ...
Page 286: ...7 32 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 350: ...8 64 8 ETHERNET CONNECTION 8 5 Precautions ...
Page 368: ...9 18 9 MELSECNET H CONNECTION PLC TO PLC NETWORK 9 5 Precautions ...
Page 420: ...11 26 11 CC Link IE CONTROLLER NETWORK CONNECTION 11 5 Precautions ...
Page 440: ...12 20 12 CC Link IE FIELD NETWORK CONNECTION 12 5 Precautions ...
Page 490: ...13 50 13 CC Link CONNECTION INTELLIGENT DEVICE STATION 13 5 Precautions ...
Page 510: ......
Page 564: ...15 54 15 INVERTER CONNECTION 15 7 Precautions ...
Page 668: ......
Page 712: ...21 12 21 MULTIPLE GT14 GT12 GT11 GT10 CONNECTION FUNCTION 21 5 Precautions ...
Page 713: ...MULTI CHANNEL FUNCTION 22 MULTI CHANNEL FUNCTION 22 1 ...
Page 714: ......
Page 760: ...22 46 22 MULTI CHANNEL FUNCTION 22 5 Multi channel Function Check Sheet ...
Page 761: ...FA TRANSPARENT FUNCTION 23 FA TRANSPARENT FUNCTION 23 1 ...
Page 762: ......
Page 860: ...REVISIONS 4 ...
Page 863: ......