This manual confers no industrial property rights or any rights of any other 

kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation 

cannot be held responsible for any problems involving industrial property rights 

which may occur as a result of using the contents noted in this manual.

Warranty

Exclusion of loss in opportunity and secondary loss from warranty liability

Regardless of the gratis warranty term, Mitsubishi shall not be liable for 

compensation to:

(1) Damages caused by any cause found not to be the responsibility of     

Mitsubishi.

(2) Loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi 

products.

(3) Special damages and secondary damages whether foreseeable or not, 

compensation for accidents, and compensation for damages to products 

other than Mitsubishi products.

(4) Replacement by the user, maintenance of on-site equipment, start-up test run 

and other tasks.

For safe use

This product has been manufactured as a general-purpose part for general 
industries, and has not been designed or manufactured to be incorporated in 
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric 
power, aerospace, medicine or passenger movement vehicles, consult with 
Mitsubishi Electric.
This product has been manufactured under strict quality control. However 
when installing the product where major accidents or losses could occur if the 
product fails, install appropriate backup or failsafe functions in the system.

HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

Side

A

Side

B

JAPANESE

ENGLISH

JY997D31001M

Side

B

Safety Precaution

 

(Read these precautions before using.)

Before using this product, please read this manual and the relevant manuals introduced

in this manual carefully and pay full attention to safety to handle the product correctly.

The precautions given in this manual are concerned with this product.

In this manual, the safety precautions are ranked as "WARNING" and "CAUTION".

Depending on circumstances, procedures indicated by "CAUTION" may also be

linked to serious results. 

In any case, it is important to follow the directions for usage.       

Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.

Indicates that incorrect handling may cause hazardous

conditions, resulting in medium or slight personal injury

or physical damage.

DESIGN PRECAUTIONS

Some failures of the GOT or cable may keep the outputs on or off.

An external monitoring circuit should be provided to check for output signals

which may lead to a serious accident.

Not doing so can cause an accident due to false output or malfunction.

If a communication fault (including cable disconnection) occurs during

monitoring on the GOT, communication between the GOT and PLC CPU is

suspended and the GOT becomes inoperative.

A system where the GOT is used should be configured to perform any

significant operation to the system by using the switches of a device other

than the GOT on the assumption that a GOT communication fault will occur.

Not doing so can cause an accident due to false output or malfunction.

Do not use the GOT as the warning device that may cause a serious accident.

An independent and redundant hardware or mechanical interlock is required to

configure the device that displays and outputs serious warning.

Failure to observe this instruction may result in an accident due to incorrect

output or malfunction.

Incorrect operation of the touch switch(s) may lead to a serious accident if the

GOT backlight is gone out. When the GOT backlight goes out, causes the

monitor screen to appear blank, while the input of the touch switch(s) remains

active. This may confuse an operator in thinking that the GOT is in

"screensaver" mode, who then tries to release the GOT from this mode by

touching the display section, which may cause a touch switch to operate.

DESIGN PRECAUTIONS

Do not bundle the control and communication cables with main-circuit, power

or other wiring.

Run the above cables separately from such wiring and keep them a minimum

of 100mm (3.94in.) apart. Not doing so noise can cause a malfunction.

Do not press the GOT display section with a pointed material as a pen or
driver. Doing so can result in a damage or failure of the display section.

Before connecting to GOT, turn ON the controller to enable the
communication. When the communication of controller is not available, a
communication error may occur in GOT.

MOUNTING PRECAUTIONS

Be sure to shut off all phases of the external power supply used by the system

before mounting or removing the GOT to/from the panel.

Not doing so can cause the unit to fail or malfunction.

When installing the battery wear an earth band etc. to avoid the static electricity.
The static electricity can cause the unit to fail or malfunction.

MOUNTING PRECAUTIONS

Use the GOT in the environment that satisfies the general specifications

described in this manual. Not doing so can cause an electric shock, fire,

malfunction or product damage or deterioration.

When mounting the GOT to the control panel, tighten the mounting screws in the

specified torque range. Undertightening can cause the GOT to drop, short circuit

or malfunction, and deteriorate the waterproof effect and oilproof effect.

Overtightening can cause a drop, short circuit or malfunction due to the damage

of the screws or the GOT, and deteriorate the waterproof effect and oilproof effect

due to distortion of the protective cover for oil, GOT or panel.

When using the GOT in the environment of oil or chemicals, use the protective
cover for oil. Failure to do so may cause failure or malfunction due to the oil or
chemical entering into the GOT.

WIRING PRECAUTIONS

Be sure to shut off all phases of the external power supply used by the system

before wiring. Failure to do so may result in an electric shock, product damage or

malfunctions.

Please make sure to ground FG terminal of the GOT power supply section by

applying 100 or less which is used exclusively for the GOT. Not doing so may

cause an electric shock or malfunction.

Correctly wire the GOT power supply section after confirming the rated voltage

and terminal arrangement of the product. Not doing so can cause a fire or failure.

Tighten the terminal screws of the GOT power supply section in the specified

torque range. Undertightening can cause a short circuit or malfunction.

Overtightening can cause a short circuit or malfunction due to the damage of the

screws or the GOT.

Exercise care to avoid foreign matter such as chips and wire offcuts entering the

GOT. Not doing so can cause a fire, failure or malfunction.

WIRING PRECAUTIONS

Plug the communication cable into the connector of the connected unit and

tighten the mounting and terminal screws in the specified torque range.

Undertightening can cause a short circuit or malfunction. Overtightening can

cause a short circuit or malfunction due to the damage of the screws or unit.

TEST OPERATION 
PRECAUTIONS

Before performing the test operations of the user creation monitor screen (such as

turning ON or OFF bit device, changing the word device current value, changing

the settings or current values of the timer or counter), read through the manual

carefully and make yourself familiar with the operation method.

During test operation, never change the data of the devices which are used to

perform significant operation for the system. False output or malfunction can

cause an accident.

STARTUP/MAINTENANCE 
PRECAUTIONS

When power is on, do not touch the terminals.

Doing so can cause an electric shock or malfunction.

Connect the battery correctly. Do not discharge, disassemble, heat, short, solder or

throw the battery into the fire. Incorrect handling may cause the battery to

generate heat, burst or take fire, resulting in injuries or fires.

Before starting cleaning or terminal screw retightening, always switch off the

power externally in all phases. Not switching the power off in all phases can cause

a unit failure or malfunction. Undertightening can cause a short circuit or

malfunction. Overtightening can cause a short circuit or malfunction due to the

damage of the screws or unit.

STARTUP/MAINTENANCE 
PRECAUTIONS

Do not disassemble or modify the unit.

Doing so can cause a failure, malfunction, injury or fire.

Do not touch the conductive and electronic parts of the unit directly.

Doing so can cause a unit malfunction or failure.

The cables connected to the unit must be run in ducts or clamped.

Not doing so can cause the unit or cable to be damaged due to the dangling,

motion or accidental pulling of the cables or can cause a malfunction due to a

cable connection fault.

When unplugging the cable connected to the unit, do not hold and pull the cable

portion. Doing so can cause the unit or cable to be damaged or can cause a

malfunction due to a cable connection fault.

Compliance with EC directive (CE Marking)

This note does not guarantee that an entire mechanical module produced in accordance
with the contents of this note will comply with the following standards. Compliance to
EMC directive for the entire mechanical module should be checked by the user/
manufacturer. For more details please contact the local Mitsubishi Electric sales site.

Attention

This product is designed for use in industrial applications.

Requirement for Compliance with EMC directive

The following products have shown compliance through direct testing (to the
identified standards) and design analysis (forming a technical construction file) to the
European Directive for Electromagnetic Compatibility (2004/108/EC) when used as
directed by the appropriate documentation.
Type :Programmable Controller (Open Type Equipment)

For more details please contact the local Mitsubishi Electric sales site.

Notes for compliance to EMC regulation

1) General notes on the use of communication cables

Any device which utilizes a data communication function is susceptible to the
wider effects of local EMC noise. Therefore, when installing any communication
cables care should always be taken with the routing and location of those cables.
The GOT units identified on the previous chapter are compliant with the EMC
requirement when the following communication cables are used.

2) General notes on Power supply

The GT1055-QSBD and GT1050-QBBD unit
requires an additional ferrite filter to be attached to
the 24V DC power supply cables. The filter should
be attached in a similar manner as shown in the
figure opposite, i.e. the power cables are wrapped
around the filter. However, as with all EMC
situations the more correctly applied precautions
t h e   b e t t e r   t h e   s y s t e m s   E l e c t r o - m a g n e t i c
Compatibility. The ferrite recommended is a TDK
ZCAT3035-1330 or similar. The ferrite should be
placed as near to the 24V DC terminals of the
GT1055-QSBD and GT1050-QBBD as possible
(which should be within 75mm of the GOT
terminal).

Associated Manuals

The following manuals are relevant to this product. When these loose manuals are
required, please consult with our local distributor.

*1 Stored in the GT Works2/GT Designer2/GT Works3/GT Designer3 in PDF

format.

For details of a PLC to be connected, refer to the PLC user's manual respectively.

Bundled Items 

「电器电子产品有害物质限制使用标识要求」的表示方式

Note: This symbol mark is for China only.

含有有害6物质的名称,含有量,含有部品
 本产品中所含有的有害 6 物质的名称,含有量,含有部品如下表所

示。

STARTUP/MAINTENANCE 
PRECAUTIONS

Do not drop or apply any impact to the battery.

If any impact has been applied, discard the battery and never use it.

The battery may be damaged by the drop or impact.

Before touching the unit, always touch grounded metal, etc. to discharge static

electricity from human body, etc.

Not doing so can cause the unit to fail malfunction.

Replace battery with GT11-50BAT by Mitsubishi electric Co. only.

Use of another battery may present a risk of fire or explosion.

Dispose of used battery promptly.

Keep away from children. Do not disassemble and do not dispose of in fire.

DISPOSAL PRECAUTIONS

When disposing of the product, handle it as industrial waste.

When disposing of batteries, separate them from other wastes according to the

local regulations. (For details of the battery directive in EU member states, refer

GOT User's Manual.)

TRANSPORTATION 
PRECAUTIONS

When transporting lithium batteries, make sure to treat them based on the

transport regulations. (Refer to User's Manual for details of the regurated

models.)

Before transporting the GOT, turn the GOT power on and check that the battery

voltage status is normal on the Time setting & display screen (utilities screen). In

addition, confirm that the adequate battery life remains on the rating plate.

Transporting the GOT with the low battery voltage or the battery the reached

battery life may unstabilize the backup data unstable during transportation.

Make sure to transport the GOT main unit and/or relevant unit(s) in the manner

they will not be exposed to the impact exceeding the impact resistance

described in the general specifications of this manual, as they are precision

devices. Failure to do so may cause the unit to fail.

Check if the unit operates correctly after transportation.

Standard

Remark

EN61131-2 : 2007
Programmable 
controllers- Equipment, 
requirement and tests

EMI

Compliance with all relevant aspects of the
standard. (Radiated Emissions)

EMS

Compliance with all relevant aspects of the
standard. (ESD, RF electromagnetic field, EFTB,
Surge, RF conducted disturbances and Power
frequency magnetic field)

GOT Unit

Existing Cables

User Made Cables

GT1055-QSBD 

and 

GT1050-QBBD

GT01-C30R4-8P 

modified as 

shown in EX.1

Those cables need to be independently
tested by the user to demonstrate EMC
compatibility when they are used with
M i t s u b i s h i   G O T   u n i t   a n d   F X

3 U

Programmable Controllers.

100mm

250mm

140mm

GT01-C30R4-8P

Comes equipped

Added by user

GOT units

Programmable
controller

Added by user

(9.84inch)

(3.93inch)

(5.51inch)

Ex.1
F = Ferrite core
Ex. NEC TOKIN - ESD-R-17S or similar

F

F

F

Manual name

Contents

Manual 

Number

(Model Code)

GT10 User's Manual 
(sold separately)

Describes the GT10 hardware-relevant
content such as part names, external
dimensions, mounting, power supply
wiring, specifications, and introduction to
option devices

JY997D24701

(09R819)

GOT1000 Series 
Connection Manual 
1/3, 2/3, 3/3
(sold separately) 

*1

Describes system configurations of the
c on n e c t i o n   m e th o d   a p p l i c a b l e   t o
GOT1000 series and cable creation
method

SH-080532ENG

(1D7M26)

GT Designer2 Version 2
Basic Operation/Data
Transfer Manual
(For GOT1000 Series)
(sold separately) 

*1

Describes methods of the GT Designer2
installation operation, basic operation for
d r a w i n g   an d   t r a n s m i t ti n g   d a ta   t o
GOT1000 series

SH-080529ENG

(1D7M24)

GT Designer2 Version2 
Screen Design Manual
(For GOT1000 Series)
1/3, 2/3, 3/3
(sold separately) 

*1

Describes specifications and settings of
t h e   o b j e c t   f u n c t i o n s   u s e d  i n  G T
Designer2

SH-080530ENG

(1D7M25)

GT Designer3 Version1
Screen Design Manual
(For GOT1000 Series)
(Fundamentals) 1/2, 2/2
(sold separately) 

*1

Describes methods of the GT Designer3
installation operation, basic operation for
d r a w i n g   an d   t r a n s m i t ti n g   d a ta   t o
GOT1000 series

SH-080866ENG

(1D7MB9)

GT Designer3 Version1
Screen Design Manual
(For GOT1000 Series)
(Functions) 1/2, 2/2
(sold separately)

 *1

Describes specifications and settings of
t h e   o b j e c t   f u n c t i o n s   u s e d  i n  G T
Designer3

SH-080867ENG

(1D7MC1)

Model Name

Remark

GT1055-QSBD

GOT main unit

(The maintenance supplies below are packed with the product.)

GT1050-QBBD

Maintenance Supplies

Quantity

Panel Mounting Bracket (with M4 

 20 screws)

4

Panel Mounting Packing

1

GT10 General Description (This manual)

1

Up to
75mm
(2.95inch)

产品中有害物质的名称及含量

本表格依据SJ/T 11364的规定编制。

○:表示该有害物质在该部件所有均质材料中的含量均在GB/T 26572

规定的限量要求以下。

×:表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T 

26572规定的限量要求。

1. Specifications

1.1 General Specifications

*1 Do not use or store the GOT under pressure higher than the atmospheric pressure of altitude 0m (0ft.). Failure to observe this instruction may cause a malfunction.

When the air inside the control panel is purged by pressurization, the surface sheet may be lifted by high pressure. As a result, the touch panel may be difficult to press,

and the sheet may be peeled off.

*2 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the

machinery within the premises. Category II applies to equipment for which electrical power is supplied from fixed facilities.

The surge voltage withstand level for up to the raged voltage of 300 V is 2500 V.

*3 This index indicates the degree to which conductive material is generated in the environment where the equipment is used.

In pollution degree 2, only non-conductive pollution occurs but temporary conductivity may be produced due to condensation.

1.2 Performance Specifications

部件名称

有害物质

(Pb)

(Hg)

(Cd)

六价铬

(Cr(VI))

多溴联苯

(PBB)

多溴

二苯醚
(PBDE)

显 示 器
GOT

外壳

印刷基板

×

Item

Specifications

GT1055-QSBD/GT1050-QBBD

Operating ambient 

temperature

Display section

0 to 50

C

Other than display section 0 to 55

C (When mounted horizontally), 0 to 50

C (When mounted vertically)

Storage ambient temperature

-20 to 60

C

Operating/Storage ambient humidity

10 to 90% RH, non-condensing (The wet bulb temperature is 39

C or less.)

Vibration resistance

Conforms to JIS 

B3502 and 

IEC61131-2

Frequency

Acceleration

Half-amplitude

Sweep Count

Under intermittent

vibration

5 to 9Hz

--

3.5mm

10 times each in X, 

Y and Z directions

9 to 150Hz

9.8m/s

2

--

Under continuous

vibration

5 to 9Hz

--

1.75mm

9 to 150Hz

4.9m/s

2

--

Shock resistance

Conforms to JIS B3502, IEC 61131-2 (147m/s

2

, 11 ms, Sine half-wave pulse, 3 times each in the X, Y, and Z directions.)

Operating atmosphere

Must be free of lamp black, corrosive gas, flammable gas, or excessive amount of electro conductive dust particles and

must be no direct sunlight. (Same as for saving)

Operating altitude

*1

2000 m (6562 ft) max.

Installation location

Inside control panel

Overvoltage category

*2

II or less

Pollution degree

*3

2 or less

Cooling method

Self-cooling

Item

Specifications

GT1055-QSBD

GT1050-QBBD

Display 
section

*1

Type

STN color liquid crystal

STN monochrome (white/blue) liquid crystal

Screen size

5.7"

Resolution

320 

 240 dots (Horizontal format)

Display size

W115(4.53) 

 H86(3.39) [mm](inch) (Horizontal format)

Display character

16-dot standard font: 40 characters 

 15 lines, 12-dot standard font: 53 characters 

 20 lines (Horizontal format)

Display color

256 colors

Monochrome (white/blue), 16 scales

Contrast adjustment

16-level adjustment

Intensity of LCD only

380 [cd/m

2

]

260 [cd/m

2

]

Life

Approx. 50,000h. (Time for display intensity to become 1/5 at operating ambient temperature of 25

C)

Backlight

Cold cathode fluorescent tube (irreplaceable by a user) backlight shutoff detection function is included.

Backlight off/screen saving time can be set.

Life

*2

Approx. 75,000h or longer (Time for display intensity reaches

50% at the operating ambient temperature of 25

C)

Approx. 54,000h or longer (Time for display intensity reaches

50% at the operating ambient temperature of 25

C)

LED (POWER LED)

Green light : Power is supplied

Orange light : Screen saving

Green / Orange flashing : Blown backlight bulb

POWER LED is not lit : Power is not supplied

Touch

panel

Number of touch keys

Maximum 50 keys/screen (Matrix resistive film touch panel)

Key size

Minimum 16 

 16 dots (per key)

Simultaneous pressing of two

(or more) areas

(2-point press)

Enable

Life

1 million times or more (operating force 0.98N max.)

Memory

C drive

*3

Flash memory ROM (Internal), for storing project data (3M bytes or less) and OS

Life (Number of write times) 100,000 times

D drive

SRAM (Internal), for storing alarm history, recipe data and time action setting value

*1 • Bright dots (always lit) and dark dots (unlit) may appear on a liquid crystal display panel. It is impossible to completely avoid this symptom, as the liquid crystal display

comprises of a great number of display elements. Flickers may be observed depending on the display color. 

Please note that these dots appear due to its characteristic and are not caused by product defect.

• Flickers and partial discoloration may be generated on the liquid crystal display panel due to the display contents or the contrast adjustment. 

However, please note that these phenomena appear due to its characteristic and are not caused by product defect. 

• There is a difference in the display brightness and the color tones between liquid crystal display panels. 

When using multiple liquid crystal display panels, please note that there is an individual difference between them. 

• A crosstalk (shadow as an extension of the display) may appear on the liquid crystal display panel. Please note that it appears due to its characteristic. 
• When the display section is seen from the outside of the display angle, the display color seems like it has changed. Please note that it is due to its characteristic.

Please note that the response time, brightness and color of the liquid crystal display panel may vary depending on the usage environmental temperature.

Especially in  the low temperature environment, the display response becomes slow due to the characteristics of the STN liquid crystal.

Please check the display response in advance for using this product.

• When the same screen is displayed for a long time, an incidental color or partial discoloration is generated on the screen due to heat damage, and it may not

disappear. To prevent heat damage, the screen saver function is effective. For details on the screen saver function, refer to the following.

 GT10 User's Manual

*2 Using the GOT Backlight OFF function can prolong the life of the backlight. For details on the Backlight OFF function, refer to the following.

 GT10 User's Manual

*3 ROM in which new data can be written without deleting the written data.
*4 Note that this does not guarantee all users' operation environment.

In addition, the product may not be used in environments under exposition of oil or chemicals for a long period of time, or in environments filled with oil-mist.

*5 Set the terminating resistor selector switch of the GOT in accordance with the connection type when adopting GOT multidrop connection. 

For details of GOT multidrop connection, refer to the following.

 GOT1000 Series Connection Manual

1.3 Power Supply Specifications

(

For details on power supply wiring, such as the allowable cable size and tightening

torque, refer to the additional manual, "GT10 User's Manual".)

*1 The GOT continues to operate even upon 5ms or shorter instantaneous

power failure.

The GOT stops operating if there is extended power failure or voltage drop,

while it automatically resumes operation as soon as the power is restored.

Battery

GT11-50BAT lithium battery

Type

Magnesium maganese dioxide lithium primary battery

Backup target

Clock data, alarm history and recipe data

Life

Approx. 5 years (Operating ambient temperature of 25)

Buzzer output (a buzzer that sounds 

when touch keys are pressed)

Single tone (LONG/ SHORT/ OFF adjustable)

Environmental protective structure

*4

Equivalent to IP67 (JEM1030) (front section)

External dimensions

W164(6.46) 

 H135(5.32) 

 D56(2.21)[mm](inch) (Excluding mounting fixtures) (Horizontal format)

Built-in 

interface

RS-422/485

Conforming to serial RS-422/485 standard, 1ch

Transmission speed: 115,200/57,600/38,400/19,200/9,600/4,800bps

Connector shape

: D-sub 9-pin (Female)

Application

: PLC communication

Terminating resistor

*5

: Open/110



/330



(Switched by terminating resistor selector switch) (At factory shipment: 330

)

RS-232

Conforming to serial RS-232 standard, 1ch

Transmission speed : 115,200/57,600/38,400/19,200/9,600/4,800bps

Connector shape

: D-sub 9-pin (Male)

Application

: PLC communication, bar code reader connection, PC communication 

(Project data upload/download, OS installation, transparent function)

USB

Conforming to serial USB (Full Speed 12Mbps), device, 1ch

Connector shape: Mini-B

Application

: PC communication (Project data upload/download, OS installation, transparent function)

GT10-50FMB

For connecting GT10-50FMB memory board

Panel cutting dimensions

W153 (6.03) 

 H121(4.77) [mm] (inch) (Horizontal format)

Weight

0.7kg (Excluding mounting fixtures)

Compatible software package

GT Designer2 Version 2.90U or later/GT Designer3 Version 1.01B or later

Item

Specifications

GT1055-QSBD

GT1050-QBBD

Item

Specifications

GT1055-QSBD

GT1050-QBBD

Input power supply voltage 24VDC (+10%  -15%)

Fuse (built-in, not 

exchangeable)

1.0A

Power consumption, 

(At backlight off)

9.84W (410mA/24VDC) 

or less, 

(4.32W (180mA/24VDC) 

or less)

9.36W (390mA/24VDC) 

or less, 

(4.32W (180mA/24VDC) 

or less)

Inrush current

15A or less (26.4VDC) 2ms

Permissible instantaneous 
power failure time

*1

Within 5ms

Noise immunity

Noise voltage: 1000Vp-p, Noise width: 1

s (by noise 

simulator of 30 to 100Hz noise frequency)

Dielectric withstand 

voltage

500VAC for 1 minute (across power supply terminals 

and earth)

Insulation resistance

10M

 or larger by insulation resistance tester 

(across power supply terminals and earth)

Grounding

Grounding with a ground resistance of 100 

 or less 

by using a ground cable that has a diameter of 1.6 

mm or more. If impossible, connect the ground cable 

to the control panel.

GT1055-QSBD, GT1050-QBBD

GT10 General Description

This manual describes the specifications of the product. Before use, read this
manual and manuals of relevant products fully to acquire proficiency in handling
and operating the product. Make sure to learn all the product information, safety
information, and precautions.
And, store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user.
Registration
The company name and the product name to be described in this manual are the
registered trademarks or trademarks of each company.

Effective Oct. 2016
Specifications are subject to change without notice.

 2008 MITSUBISHI ELECTRIC CORPORATION

Manual Number

JY997D31001M

Date

Oct. 2016