16 GOT SELF CHECK (DEBUG)
16.3 FX3U-ENET-ADP Communication Setting Function
261
16
16.3
FX3U-ENET-ADP Communication Setting Function
In GX Works2, the communication set value of the FX3U-ENET-ADP stored in the CPU can be changed.
This function is not available when the communication set value of the FX3U-ENET-ADP is not set in advance in the CPU.
Communication setting in the CPU
In GX Works2, set in advance the communication set value of the FX3U-ENET-ADP to the CPU.
For the details of the communication setting, refer to the following.
FX3U-ENET-ADP User's manual
Specifications
System configuration
This section describes the system configuration of the FX3U-ENET-ADP communication setting function.
For the setting method in each connection form, used communication unit/cable and cautions on connection form, refer to the
following manual.
GOT2000 Series Connection Manual For GT Works3 Version1
■
Required basic system application
■
Connection type
( : Applicable, : Partly restricted, : Inapplicable)
■
Communication setting items
The table below shows the communication setting items and setting range.
*1 Set the value "0.0.0.0" when not using the subnet mask pattern and default router IP address.
Operating system
Version
Basic system application
-
Communication driver
MELSEC-FX
-
Function
Connection type between GOT and controller
Name
Description
Direct CPU
connection
GOT multidrop connection
FX3U-ENET-ADP communication
setting function
The communication set value of the FX3U-ENET-ADP
stored in the CPU can be changed.
Communication setting items
Setting range
Remark
IP address
0.0.0.1 to 223.255.255.254
If a value outside the setting range is entered, the error message "SET
NUMBER IS INCORRECT." appears.
Subnet mask pattern
*1
192.0.0.0 to 255.255.255.252
Default router IP address
*1
0.0.0.1 to 223.255.255.254
Summary of Contents for GOT SIMPLE Series
Page 1: ...GOT SIMPLE Series User s Manual GS21 model ...
Page 2: ......
Page 20: ...18 MEMO ...
Page 24: ...22 1 OVERVIEW 1 1 Features MEMO ...
Page 34: ...32 3 SPECIFICATIONS 3 4 GOT Connector Specifications MEMO ...
Page 40: ...38 4 PART NAME 4 3 Bottom MEMO ...
Page 62: ...60 7 WIRING 7 2 Wiring Inside and Outside the Panel MEMO ...
Page 76: ...74 10 LANGUAGE SETTING LANGUAGE 10 1 Display language setting MEMO ...
Page 130: ...128 12 DISPLAY AND OPERATION SETTINGS GOT SET UP 12 7 IP Filter Setting MEMO ...
Page 160: ...158 14 CLOCK SETTINGS TIME SETTING AND DISPLAY 14 1 Time Setting and Display MEMO ...
Page 268: ...266 16 GOT SELF CHECK DEBUG 16 3 FX3U ENET ADP Communication Setting Function MEMO ...
Page 274: ...272 17 MAINTENANCE 17 3 Clean MEMO ...
Page 280: ...278 20 ERROR MESSAGE LIST MEMO ...
Page 296: ...294 22 TROUBLESHOOTING 22 1 GOT Restoration Sheets MEMO ...
Page 298: ...296 23 CONNECTION MEMO ...
Page 305: ...24 APPENDIX 24 1 External Dimensions 303 24 MEMO ...
Page 309: ......