Appendix 3 Buffer Memory
147
A
Extended diagnostic information read response area
■
Extended diagnostic information read response area (Un\G23457 to Un\G23583)
This area stores the result of the extended diagnostic information read request.
Completion of operation with an error causes addresses Un\G23458 to Un\G23583 to be set to 0H.
Parameter setting status area (Active station)
■
Parameter setting status area (Active station) (Un\G23584 to Un\G23587)
This area indicates the DP-Slave set as normal DP-Slaves by slave parameters.
Setting status is stored when 'Communication READY signal' (Un\G1.bB) turns on.
• 0: Reserved station setting or not-configured station setting
• 1: Normal DP-Slave
The values in the table indicate which number of DP-Slave each bit represents.
Address
Bit
Name
Description
Initial
value
Un\G23457
Read results code
Stores the read result
• A200H: Completed successfully
• Other than A200H: Completed with an error (
0000H
Un\G23458
Size
Stores the data size of the extended diagnostic information stored in
addresses Un\G23459 to Un\G23583.
• 0006H to 00F4H: Data size of extended diagnostic information (Unit: byte)
0000H
Un\G23459
b8 to b15
Status 1 + status 2
Stores the status 1 information.
• 00H: Normal
• Other than 00H:
Page 145 Status 1 and status 2 information
00H
b0 to b7
Stores the status 2 information.
• 00H: Normal
• Other than 00H:
Page 145 Status 1 and status 2 information
00H
Un\G23460
b8 to b15
Status 3 + FDL address of
DP-Master
Stores the status 3 information (whether any piece of extended diagnostic
information other than the one sent this time is stored in the DP-Slaves).
• 00H: No other extended diagnostic information is stored.
• 80H: Other extended diagnostic information is stored.
00H
b0 to b7
Stores the FDL address of the DP-Master.
Stores FFH for a DP-Slave that has not started data exchange.
• 00H to 7DH (0 to 125): FDL address
00H
Un\G23461
Ident No.
Stores the Ident No. for the DP-Slaves.
0000H
Un\G23462 to
Un\G23583
Extended diagnostic
information
Stores the extended diagnostic information (244 bytes maximum).
0000H
Address
b15
b14
b13
b12
b11
b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
Un\G23584
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Un\G23585
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
Un\G23586
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
Un\G23587
64
63
62
61
60
59
58
57
56
55
54
53
52
51
50
49
Summary of Contents for FX5-DP-M
Page 1: ...MELSEC iQ F FX5 User s Manual PROFIBUS ...
Page 2: ......
Page 9: ...7 MEMO ...
Page 12: ...10 INDEX 168 REVISIONS 170 WARRANTY 171 TRADEMARKS 172 ...
Page 13: ...11 CONTENTS ...
Page 19: ...1 DESCRIPTION 17 1 MEMO ...
Page 100: ...98 9 PROGRAMMING 9 2 DP Master settings DP Slave FDL address 2 ...
Page 101: ...9 PROGRAMMING 9 2 DP Master settings 99 9 DP Slave FDL address 3 ...
Page 108: ...106 9 PROGRAMMING 9 8 Program Example of the Global Control Function ...
Page 109: ...9 PROGRAMMING 9 8 Program Example of the Global Control Function 107 9 ...
Page 110: ...108 9 PROGRAMMING 9 8 Program Example of the Global Control Function ...
Page 112: ...110 9 PROGRAMMING 9 9 Program Example of Acyclic Communication Acyclic Communication ...
Page 114: ...112 9 PROGRAMMING 9 10 Program Example of the Alarm Acquisition Function ...
Page 169: ...APPX Appendix 4 Processing Time 167 A MEMO ...
Page 175: ......