65
Operation Procedures for Functions
3
3.2.5 Parameter clear
You can perform the "parameter clear" and "all parameter clear".
Switch to the PU operation mode before performing any operation.
•
Clear Pr. .......................... Returns (initializes) the parameters to the factory settings with the exception of
the some parameters (
Pr. 75
and calibration values in
Pr. 900 to 905
).
•
Clear All........................... Initializes all parameters with the exception of
Pr. 75
.
(1) Parameter clear
1
Press .
The function menu is called.
2
Using
/
, move the
cursor to "4 Pr. Clear".
3
Press .
The parameter menu
appears.
4
Select the "Clear Pr.".
Using
/
, move the
cursor to "1" and press the
.
2 PU Oper
3 Pr.List
1 MONITOR
4 Pr.Clear
2 PU Oper
3 Pr.List
1 MONITOR
4 Pr.Clear
2 Clear All
1 Clear Pr.
2 Clear All
1 Clear Pr.
5
"Clear Pr." is selected, and
the confirmation screen for
clearing execution is
displayed.
6
Press .
The parameters are
initialized.
When canceling the
initialization, press
on
the confirmation screen.
Exec<WRITE>
Cancel<ESC>
Clear Pr.
COmpleted
COmpleted
Clear Pr.