![Mitsubishi Electric FR-F820-00046 Instruction Manual Download Page 152](http://html.mh-extra.com/html/mitsubishi-electric/fr-f820-00046/fr-f820-00046_instruction-manual_1811886152.webp)
Frequently-used parameters (simple mode parameters)
Basic operation
4 - 12
Initial value for the FR-F820-00046(0.75K) or lower and FR-F840-00023(0.75K) or lower.
Initial value for the FR-F820-00077(1.5K) to FR-F820-00167(3.7K) and the FR-F840-00038(1.5K) to
FR-F840-00083(3.7K).
Initial value for the FR-F820-00250(5.5K), FR-F820-00340(7.5K), FR-F820-00126(5.5K), and FR-F840-
00170(7.5K).
Initial value for the FR-F820-00490(11K) to FR-F820-01540(55K), FR-F820-00250(11K) to
FR-F840-00770(37K).
!
Initial value for the FR-F820-01870(45K), FR-F820-02330(55K), FR-F840-00930(45K), and FR-F840-
01160(55K).
Initial value for the FR-F820-03160(75K) or higher and FR-F840-01800(75K) or higher.
$
For the FR-F820-02330(55K) or lower and FR-F840-01160(55K) or lower.
%
For the FR-F820-03160(75K) or higher and FR-F840-01800(75K) or higher.
"
Initial value for the FR-F820-00340(7.5K) or lower and FR-F840-00170(7.5K) or lower.
#
Initial value for the FR-F820-00490(11K) or higher and FR-F840-00250(11K) or higher.
FM denotes the initial value for the FM type inverter that has the terminal FM, and CA denotes the
initial value for the CA type inverter that has the terminal CA.
7
F010
Acceleration time
0.1 s
0–3600 s
Sets the acceleration time.
15 s
8
F011
Deceleration time
0.1 s
10 s
0–3600 s
Sets the deceleration time.
30 s
9
H000
C103
Electronic thermal
O/L relay
0.01 A
$
Rated
inverter
current
0–500 A
$
Protects the motor from heat.
Set the rated motor current.
0.1 A
%
0–3600 A
%
79
D000
Operation mode
selection
1
0
0–4, 6, 7
Select the start and frequency command
sources.
125
T022
Terminal 2
frequency setting
gain frequency
0.01 Hz 60 Hz 50 Hz
0–590 Hz
Allows the frequency at the maximum
potentiometer setting (5 V in the initial
setting) to be changed.
126
T042
Terminal 4
frequency setting
gain frequency
0.01 Hz 60 Hz 50 Hz
0–590 Hz
Allows the frequency at the maximum
current input (20 mA in the initial setting)
to be changed.
160
E440
User group read
selection
1
9999
0
0, 1, 9999
Restricts the parameters that are read by
the operation panel and the parameter
unit.
998
E430
PM parameter
initialization
1
0
0, 12, 14,
112, 114,
8009, 8109,
9009, 9109
Selects the PM motor control and set the
parameters that are required to drive a PM
motor.
999
E431
Automatic
parameter setting
1
9999
1, 2, 10, 11,
12, 13, 20,
21, 30, 31,
9999
Changes parameter settings as a batch. The
target parameters include communication
parameters for the Mitsubishi's human
machine interface (GOT) connection and
the parameters for the rated frequency
settings of 50 Hz/60 Hz.
Pr.
Pr.
group
Name
Unit
Initial value
Range
Application
Refer
to
page
FM
CA
Tab. 4-9:
Simple mode parameters (2)
Summary of Contents for FR-F820-00046
Page 2: ......
Page 4: ......
Page 114: ...System configuration for Ethernet communication FR F800 E Installation and wiring 2 86 ...
Page 172: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 812: ...Inverter to inverter link function FR F800 E Parameters 5 640 ...
Page 900: ...Outline dimension drawings Specifications 8 26 ...
Page 929: ...Appendix EC Declarations of Conformity FR F800 A 29 ...
Page 930: ...EC Declarations of Conformity Appendix A 30 ...
Page 931: ...Appendix EC Declarations of Conformity FR F800 A 31 ...
Page 932: ...EC Declarations of Conformity Appendix A 32 ...
Page 933: ...Appendix EC Declarations of Conformity FR F800 A 33 ...
Page 934: ...EC Declarations of Conformity Appendix A 34 ...
Page 935: ...Appendix EC Declarations of Conformity FR F800 A 35 ...
Page 936: ...EC Declarations of Conformity Appendix A 36 ...
Page 937: ...Appendix EC Declarations of Conformity FR F800 A 37 ...
Page 938: ...EC Declarations of Conformity Appendix A 38 ...
Page 939: ......