13
PARAMETER
33
Frequency jump 2A
0 to 400Hz,
9999
9999
34
Frequency jump 2B
0 to 400Hz,
9999
9999
35
Frequency jump 3A
0 to 400Hz,
9999
9999
36
Frequency jump 3B
0 to 400Hz,
9999
9999
37
Speed display
0, 1 to 9998
0
41
Up-to-frequency
sensitivity
0 to 100%
10%
42
Output frequency
detection
0 to 400Hz
6Hz
43
Output frequency
detection for reverse
rotation
0 to 400Hz,
9999
9999
44
Second acceleration/
deceleration time
0 to 3600/360s
5s
45
Second deceleration
time
0 to 3600/360s,
9999
9999
46
Second torque boost
0 to 30%, 9999
9999
47
Second V/F
(base frequency)
0 to 400Hz,
9999
9999
48
Second stall
prevention operation
current
0.1 to 120%
110%
49
Second stall
prevention operation
frequency
0 to 400Hz,
9999
0Hz
50
Second output
frequency detection
0 to 400Hz
30Hz
51
Second electronic
thermal O/L relay
0 to 500A,
9999/
0 to 3600A,
9999 *
1
9999
52
DU/PU main display
data selection
0, 5, 6, 8 to 14,
17, 20, 23 to 25,
50 to 57, 100
*
2
0
54
CA terminal function
selection
1 to 3, 5, 6,
8 to 14, 17, 21,
24, 50, 52, 53
*
2
1
55
Frequency
monitoring reference
0 to 400Hz
50Hz
56
Current monitoring
reference
0 to 500A/
0 to 3600A *
1
Rated
inverter
output
current
57
Restart coasting time
0, 0.1 to 5s,
9999/
0, 0.1 to 30s,
9999 *
1
9999
58
Restart cushion time
0 to 60s
1s
59
Remote function
selection
0, 1, 2, 3
0
60
Energy saving
control selection
0, 4, 9
0
65
Retry selection
0 to 5
0
66
Stall prevention
operation reduction
starting frequency
0 to 400Hz
50Hz
Parameters
Name
Setting Range
Initial Value
67
Number of retries at
alarm occurrence
0, 1 to 10,
101 to 110
0
68
Retry waiting time
0 to 10s
1s
69
Retry count display
erase
0
0
70
Special regenerative
brake duty *
3
0 to 10%
0%
71
Applied motor
0, 1, 2, 20
0
72
PWM frequency
selection
0 to 15/
0 to 6, 25 *
1
2
73
Analog input
selection
0 to 7, 10 to 17
1
74
Input filter time
constant
0 to 8
1
75
Reset selection/
disconnected PU
detection/PU stop
selection
0 to 3, 14 to 17,
100 to 103,
114 to 117
*
4
14
76
Alarm code output
selection
0, 1, 2
0
77
Parameter write
selection
0, 1, 2
0
78
Reverse rotation
prevention selection
0, 1, 2
0
79
Operation mode
selection
0, 1, 2, 3, 4, 6, 7
0
80
Motor capacity
(simple magnetic
flux vector control)
0.4 to 55kW,
9999/
0 to 3600kW,
9999 *
1
9999
90
Motor constant (R1)
0 to 50
Ω
, 9999/
0 to 400m
Ω
,
9999 *
1
9999
100
V/F1 (first frequency)
0 to 400Hz,
9999
9999
101
V/F1 (first frequency
voltage)
0 to 1000V
0V
102
V/F2
(second frequency)
0 to 400Hz,
9999
9999
103
V/F2 (second
frequency voltage)
0 to 1000V
0V
104
V/F3 (third
frequency)
0 to 400Hz,
9999
9999
105
V/F3 (third frequency
voltage)
0 to 1000V
0V
106
V/F4
(fourth frequency)
0 to 400Hz,
9999
9999
107
V/F4 (fourth
frequency voltage)
0 to 1000V
0V
108
V/F5 (fifth frequency)
0 to 400Hz,
9999
9999
109
V/F5 (fifth frequency
voltage)
0 to 1000V
0V
117
PU communication
station number
0 to 31
0
118
PU communication
speed
48, 96, 192, 384
192
Parameters
Name
Setting Range
Initial Value
*1
The setting depends on capacities. (01160 or less/01800 or more)
*2
Setting of "9" can be made for the 01800 or more.
*3
Setting can be made for the 01800 or more.
*4