Control circuit specifications
2.3.4
Connection to the PU connector
Using the PU connector, you can perform communication operation from the parameter unit (FR-PU07), enclosure surface
operation panel (FR-PA07) or a personal computer etc.
Refer to the figure below to open the PU connector cover.
When connecting the parameter unit or enclosure surface operation panel using a connection cable
Use the optional FR-CB2
or connector and cable available on the market.
Insert the cable plugs securely into the PU connector of the drive unit and the connection connector of the FR-PU07 or FR-
PA07 along the guide until the tabs snap into place.
REMARKS
Refer to the following when fabricating the cable on hte user side. Keep the total cable length within 20m.
Examples of product available on the market (as of February 2012)
PU connector
Place a flathead screwdriver, etc. in a slot
and push up the cover to open.
To open the cover
STF FWD PU
Parameter unit FR-PU07
(option)
PU connector
Parameter unit connection cable
(FR-CB2
)(option)
Operation panel FR-PA07
(option)
Product
Type
Maker
1)
10BASE-T cable
SGLPEV-T (Cat5e/300m)
24AWG
4P
Mitsubishi Cable Industries, Ltd.
2)
RJ-45 connector
5-554720-3
Tyco Electronics Corporation