219
Communication operation and setting
[Fault data]
for details of fault description
[Run command]
The signal is the default setting. The description changes depending on the setting of
Pr.180 to Pr.184 (input terminal function selection)
.
The signal is the default setting. Reset cannot be controlled by the network, bit 11 is invalid in the initial status. When using bit 11, change the signal with
Pr.184 RES terminal function selection
(page 138)
(Reset can be executed with the instruction code HFD)
When
Pr.551
= "2" (PU Mode command source is PU connector), only forward rotation and reverse rotation can be used.
Item
Instruction
Code
Bit
Length
Description
Example
Run
command
HFA
8 bits
b0: Current input selection (Fixed)
b1: Forward rotation command
(Fixed)
b2: Reverse rotation command
(Fixed)
b3: RL (low speed operation
command)
(Variable))
b4: RM (middle speed operation
command
(Variable))
b5: RH (high speed operation
command
(Variable))
b6: Second function selection
(Fixed)
b7: MRS (output stop
(Variable))
Run
command
(expansion)
HF9
16 bits
b0: Current input selection (Fixed)
b1: Forward rotation command
(Fixed)
b2: Reverse rotation command
(Fixed)
b3: RL (low speed operation
command
(Variable))
b4: RM (middle speed operation
command
(Variable))
b5: RH (high speed operation
command
(Variable))
b6: Second function selection
(Fixed)
b7: MRS (output stop
(Variable))
b8:
b9:
b10:
b11: RES (Reset (Variable))
b12:
b13:
b14:
b15:
For read data H3010
(Previous fault... THT)
(Latest fault... OC1)
0
1
0
1 0 0 0 0
0
1
0
0
0
0
0
0
b15
b8b7
b0
Latest fault
(HA1)
Previous fault
(H30)
Fault record display example (instruction code H74)
Data
Definition
H00
No fault
present
H10
E.OC1
H11
E.OC2
H12
E.OC3
H20
E.OV1
H21
E.OV2
H22
E.OV3
H30
E.THT
H31
E.THM
H40
E.FIN
H52
E.ILF
H60
E.OLT
H61
E.SOT
H70
E.BE
H80
E.GF
H81
E.LF
H90
E.OHT
HA0
E.OPT
HA1
E.OP1
HB0
E.PE
HB1
E.PUE
HB2
E.RET
HB3
E.PE2
HC0
E.CPU
HC5
E.IOH
Data
Definition
HC7
E.AIE
HC8
E.USB
HC9
E.SAF
HD0
E.OS
HD1
E.OSD
HD3
E.OD
HDD
E.OA
HF1
E.1
HF5
E.5
HF6
E.6
HF7
E.7
HFD
E.13
Data
Definition
0
0
0
0
0
0
1
0
b7
b0
[Example 1] H02... Forward rotation
[Example 2] H00... Stop
0
0
0
0
0
0
0
0
b7
b0
0
0
0
0
0
0
1
0
b0
[Example 1] H0002... Forward rotation
0
0
0
0
0
0
0
0
b15
0
0
0
0
0
0
0
0
b0
[Example 2] H0800... Low speed operation
(When
Pr. 184 RES terminal function selection
is set to "0")
0
0
0
0
1
0
0
0
b15