![Mitsubishi Electric FR-D710W-0.1K Instruction Manual Download Page 156](http://html.mh-extra.com/html/mitsubishi-electric/fr-d710w-0-1k/fr-d710w-0-1k_instruction-manual_239791156.webp)
154
Frequency setting by analog input (terminal 2, 4)
4.16.3 Bias and gain of frequency setting voltage (current)
(Pr. 125, Pr. 126, Pr. 241, C2 (Pr. 902) to C7 (Pr. 905))
[Frequency setting bias/gain parameter]
∗1
The above parameters can be set when
Pr. 160 Extended function display selection
= "0".
∗2
The parameter number in parentheses is the one for use with the operation panel (PA02) for the FR-E500 series or parameter unit (FR-PU04/FR-PU07).
∗3
This parameter allows its setting to be changed during operation in any operation mode even if "0" (initial value) is set in
Pr. 77 Parameter write selection
.
You can set the magnitude (slope) of the output frequency as desired in relation to the frequency setting signal (0 to
5VDC, 0 to 10VDC or 4 to 20mADC).
Set
Pr. 267
and voltage/current input switch to switch among 0 to 5VDC, 0 to 10VDC, and 0 to 20mADC input using
terminal 4.
Parameter
Number
Name
Initial
Value
Setting
Range
Description
125
Terminal 2 frequency setting
gain frequency
60Hz
0 to 400Hz
Frequency of terminal 2 input gain (maximum).
126
Terminal 4 frequency setting
gain frequency
60Hz
0 to 400Hz
Frequency of terminal 4 input gain (maximum).
241
Analog input display unit
switchover
0
0
Displayed in %
Unit for analog input display.
1
Displayed in V/mA
C2 (902)
Terminal 2 frequency setting
bias frequency
0Hz
0 to 400Hz
Frequency on the bias side of terminal 2 input.
C3 (902)
Terminal 2 frequency setting
bias
0%
0 to 300%
Converted % of the bias side voltage of terminal 2
input.
C4 (903)
Terminal 2 frequency setting
gain
100%
0 to 300%
Converted % of the gain side voltage of terminal 2
input.
C5 (904)
Terminal 4 frequency setting
bias frequency
0Hz
0 to 400Hz
Frequency on the bias side of terminal 4 input.
C6 (904)
Terminal 4 frequency setting
bias
20%
0 to 300%
Converted % of the bias side current (voltage) of
terminal 4 input.
C7 (905)
Terminal 4 frequency setting
gain
100%
0 to 300%
Converted % of the gain side current (voltage) of
terminal 4 input.