Appendix 1
Instruction code list
Instruction codes are used to read and write parameters by using the Mitsubishi inverter protocol via RS-485 communication. (For the RS-485
communication, refer to
.)
For "parameter copy", "parameter clear", and "all parameter clear", "
" indicates the function is available, and
indicates the function is not
available.
Communication parameters that are not cleared by parameter clear (all clear) via the RS-485 communication. (For the RS-485 communication,
refer to
Pr.
Name
Instruction
code
PARAMETER
Rea
d
Wr
it
e
Extended
Copy
Clear
All
clear
30
Reset selection during
power supply to main
circuit
1E 9E 0
57
Restart selection
39 B9 0
65
Parameter for manufacturer setting. Do not set.
67
Number of retries at fault
occurrence
43 C3 0
68
Parameter for manufacturer setting. Do not set.
69
Retry count display
erase
45 C5 0
75
Reset selection/
disconnected PU
detection/reset limit
4B CB 0
77
Parameter write
selection
4D CD 0
117
PU communication
station number
11 91 1
118
PU communication
speed
12 92 1
119
PU communication stop
bit length / data length
13 93 1
120
PU communication
parity check
14 94 1
121
Number of PU
communication retries
15 95 1
122
PU communication
check time interval
16 96 1
123
PU communication
waiting time setting
17 97 1
124
PU communication CR/
LF selection
18 98 1
161
Key lock operation
selection
01 81 2
168
Parameter for manufacturer setting. Do not set.
169
170 Watt-hour meter clear
0A 8A 2
178
RDI terminal function
selection
12 92 2
187
OH terminal function
selection
1B 9B 2
189
RES terminal function
selection
1D 9D 2
190
RDB terminal function
selection
1E 9E 2
191
RDA terminal function
selection
1F 9F 2
192
IPF terminal function
selection
20 A0 2
193
RSO terminal function
selection
21 A1 2
194
FAN terminal function
selection
22 A2 2
195
ABC1 terminal function
selection
23 A3 2
248
Self power management
selection
38 B8 2
255 Life alarm status display 3F BF 2
256
Inrush current limit
circuit life display
40 C0 2
257
Control circuit capacitor
life display
41 C1 2
261
Power failure stop
selection
45 C5 2
268
Monitor decimal digits
selection
4C CC 2
269 Parameter for manufacturer setting. Do not set.
290
Monitor negative output
selection
62 E2 2
296 Password lock level
68 E8 2
297 Password lock/unlock
69 E9 2
331
Parameter for manufacturer setting. Do not set.
332
333
334
335
336
337
341
342
Communication
EEPROM write selection
2A AA 3
343 Parameter for manufacturer setting. Do not set.
503 Maintenance timer 1
03 83 5
504
Maintenance timer 1
warning output set time
04 84 5
514
Emergency drive
dedicated retry waiting
time
0E 8E 5
515
Emergency drive
dedicated retry count
0F 8F 5
523
Emergency drive mode
selection
17 97 5
539
Parameter for manufacturer setting. Do not set.
549
563
Energization time
carrying-over times
3F BF 5
598 Undervoltage level
62 E2 5
652
Parallel operation
communication check
time
34 B4 6
663
Control circuit
temperature signal
output level
3F BF 6
686 Maintenance timer 2
56 D6 6
687
Maintenance timer 2
warning output set time
57 D7 6
688 Maintenance timer 3
58 D8 6
689
Maintenance timer 3
warning output set time
59 D9 6
Pr.
Name
Instruction
code
PARAMETER
R
ead
Wr
it
e
Extended
Copy
Clear
All
clear