5. PARAMETERS
5.1 Parameter List
5
PARAMETERS
This chapter explains the function setting for use of this product.
Always read the instructions before use.
5.1
Parameter List
5.1.1
Parameter list (by parameter number)
Set the necessary parameters to meet the load and operational specifications. Parameter setting, change, and check can be
made on the operation panel. Install the operation panel of the inverter on the converter unit.
NOTE
• Refer to
for instruction codes for communication and availability of Parameter clear, All parameter clear, and
Parameter copy.
Pr.
Pr.
group
Name
Setting range
Minimum
setting
increments
Initial
value
Refer to
page
Customer
setting
30
E300
Reset selection during power
supply to main circuit
0, 100
1
0
57
A702
Restart selection
0, 9999
1
9999
65
H300
Retry selection
0 to 4
1
0
67
H301
Number of retries at fault
occurrence
0 to 10, 101 to 110
1
0
68
H302
Retry waiting time
0.1 to 600 s
0.1 s
1 s
69
H303
Retry count display erase
0
1
0
75
—
Reset selection/disconnected PU
detection/reset limit
14 to 17, 114 to 117
1
14
E100
Reset selection
0, 1
0
E101
Disconnected PU detection
E107
Reset limit
77
E400
Parameter write selection
1, 2
1
2
117
N020
PU communication station number
0 to 31
1
0
118
N021
PU communication speed
48, 96, 192, 384, 576,
768, 1152
1
192
119
—
PU communication stop bit length
/ data length
0, 10
1
1
N022
PU communication data length
0, 1
0
N023
PU communication stop bit length
0, 1
1
120
N024
PU communication parity check
0 to 2
1
2
121
N025
PU communication retry count
0 to 10, 9999
1
1
122
N026
PU communication check time
interval
0, 0.1 to 999.8 s, 9999
0.1 s
9999
123
N027
PU communication waiting time
setting
0 to 150 ms, 9999
1 ms
9999
124
N028
PU communication CR/LF
selection
0 to 2
1
1
161
E200
Key lock operation selection
0, 10
1
0
168
E000
Parameter for manufacturer setting. Do not set.
E080
169
E001
E081
170
M020
Watt-hour meter clear
0, 10, 9999
1
9999