64
7.2.4
Class 0x05 (DeviceNet connection object)
FR-A8ND supports only Polled I/O and Explicit Msg, not Bit-Strobed I/O. In addition, Instance 4 to 6 are Explicit messaging
Instance.
Class 0x05 Instance 1 attribute (Explicit messaging connection)
Class 0x05 Instance 1
Attribute
ID
Access
Name
Data
type
No. of
data bytes
Range
Definition
1
Get
State
USINT
1
00
Non-existent
01
Configuring
03
Established
04
Timed out
2
Get
Instance Type
USINT
1
00
Explicit messaging connection
3
Get
Transport Trigger
class
BYTE
1
00 to 0xFF
0x83: Server Transport Class 3
4
Get
Produced
Connection ID
UINT
2
0 to 0xFFFF
CAN ID that the inverter sends
5
Get
Consumed
Connection ID
UINT
2
0 to 0xFFFF
CAN ID that the inverter receives
6
Get
Initial Command
Characteristics
BYTE
1
00 to 0xFF
The value defines sent and received message
groups.
0x21: Both send and receive messages are
Group 2 message
7
Get
Produced
Connection Size
UINT
2
0 to 0xFFFF
This value specifies the maximum number of
Message Body bytes that a module is able to
transmit across the connection.
7: 7 byte