ENCODER FEEDBACK CONTROL
Mount FR-A8AP to an FR-A800 series inverter to perform encoder feedback control under V/F control or Advanced magnetic
flux vector control.
This controls the inverter output frequency so that the motor speed is constant to the load variation by detecting the motor
speed with the speed detector (encoder) to feed back to the inverter.
For the details of the parameters used for encoder feedback control, refer to the Instruction Manual (Detailed) of the inverter.
5.1 Wiring examples
R/L1
S/L2
T/L3
SF-JR motor with encoder
U
V
W
U
V
W
E
C
∗3
∗1
∗2
∗4
∗5
R
PA1
FR-A8AP
PA2
PB1
PB2
PG
PG
SD
SD
Differential
Terminating
resistor ON
OFF
Complementary
A
N
H
K
IM
Forward rotation start
Reverse rotation start
Contact input common
Frequency setting
potentiometer
STF
STR
SD
10
2
5
Encoder
Earth
(Ground)
Inverter
5 VDC power
supply
∗6
(+)
(-)
Three-phase
AC power supply
MCCB
MC