(N) Operation via communication and its settings
Parameters
5 - 616
Data definitions
●
Control code
●
Inverter station number
●
Specify the station number of the inverter which communicates with the computer.
●
Instruction code
●
Specify the processing request, for example, operation or monitoring, given by the computer to
the inverter. Hence, the inverter can be run and monitored in various ways by specifying the
instruction code appropriately. (Refer to page 5-623.)
●
Data
●
Indicates the data such as frequency and parameters transferred to and from the inverter. The
definitions and ranges of set data are determined in accordance with the instruction codes. (Refer
to page 5-623.)
●
Waiting time
●
Specify the waiting time between the receipt of data at the inverter from the computer and the
transmission of reply data. Set the waiting time in accordance with the response time of the
computer in the range of 0 to 150 ms in 10 ms increments. (For example; 1=10 ms, 2= 20 ms)
Signal name
ASCII Code
Description
STX
H02
Start Of Text (Start of data)
ETX
H03
End Of Text (End of data)
ENQ
H05
Inquiry (Communication request)
ACK
H06
Acknowledge (No data error detected)
LF
H0A
Line Feed
CR
H0D
Carriage Return
NAK
H15
Negative Acknowledge (Data error detected)
Tab. 5-270:
Control codes
I002736E
Fig. 5-310:
Specifying the waiting time
NOTES
When Pr. 123 or Pr. 337 (Waiting time setting) ≠ "9999", create a communication request data
without "waiting time" in the data format. (The number of characters decreases by 1.)
The data check time varies depending on the instruction code. (Refer to page 5-618.)
=
+
Computer
Computer
Inverter
Inverter
Inverter data processing time
Waiting time
(setting x 10 ms)
data check time
(About 10 to 30ms,
which depends on the
instruction code)
Inverter data processing time
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......