Operation panel FR-DU07
Operation
4 - 6
4.3.2
Basic operation (factory setting)
I001060E
Fig. 4-4:
Overview of the basic functions of the operation panel FR-DU07
Operation mode switch over
At powering on (external operation mode)
Monitor/frequency setting
P
a
ra
meter setting
Alar
m histor
y
PU Jog operation mode
PU operation mode
(output frequency monitor)
Value change
Example
and frequency flicker
Frequency setting has been
written and completed!
Output current monitor
Output voltage monitor
Parameter setting mode
Display the
current setting
Example
Parameter and a setting value
flicker alternately.
Parameter clear
Parameter all clear
Alarm clear
Parameter write is completed!
Parameter copy
The operation for displaying the alam history is explained in section 7.5.
The past eight alams can be displayed.
(The latest alarm is ended by „.“.)
When no alarm history exists,
is displayed.