55
Dedicated function list
4 TENSION CONTROL
4.1 Dedicated function list
Refer to
for the winding diameter compensation function.
4.2 System configuration example
Item
Description
Tension
control
Taper function
Set a taper ratio.
Inertia compensation function
Compensates the inertia during acceleration and during deceleration separately
using external signals.
Mechanical loss compensation
function
Interpolates linearly against the speed (with 5 break points).
Common
Dedicated input signal
Dancer/tension control selection, inertia compensation acceleration, inertia
compensation deceleration, inertia compensation second acceleration/
deceleration time selection, winding diameter measurement, stall operaion
Dedicated output signal
Winding diameter calculation completion
Dedicated monitored item
Tension command, mechanical loss compensation, inertia compensation
IM
FR-A700-A1
STF/STR
X58
X57
IM
FR-A700
2
STF/STR
Middle shaft / speed control
Line speed detection
Line speed
4
Dancer/tension control selection
Inertia compensation
acceleration signal
X83
Main speed command
Start command
Torque command
FR-A7AZ
Start command
6
Inertia compensation
deceleration signal
Stall operation signal
Speed limit
2
Encoder
Encoder
FR-A7AP
FR-A7AP
PLC
Vector control
Minimum diameter
Maximum diameter
Reduction gear
X92