background image

2. Safety Precautions

• Before installing the unit, make sure you read all the “Safety precautions”.
• The “Safety precautions” provide very important points regarding safety. Make sure you follow them.

Symbols used in the text

WARNING

Describes precautions that should be observed to prevent danger of injury or death to the
user.

CAUTION

Describes precautions that should be observed to prevent damage to the unit.

WARNING

• Do not install it by yourself (customer). Ask dealer or authorized company to install the

accessory.

• Incomplete installation could cause injury.
• When you notice exceptionally abnormal noise or vibration, stop operation and contact

your dealer.

CAUTION

• Use proper safety equipment for the Installation work.
• Tighten all screws as specified in the instructions. Over tightening screws can cause

damage to parts.

• Not following properly installation instructions may result in air flow not passing through

the filters, causing poor performance and other problems.

• Do not place polyethylene bags in reach of young children. Putting them over the head

will block breathing passages, which could result in suffocation.

FBM-Series

© 2019 Mitsubishi Electric US, Inc.

6

Specifications are subject to change without notice.

Summary of Contents for FBM Series

Page 1: ...UBISHI ELECTRIC US INC Filter Boxes FBM Series For use with PEFY PEAD Indoor Units INSTALLATION MANUAL FOR INSTALLER For safe and correct use please read this installation manual thoroughly before installing these component ...

Page 2: ......

Page 3: ... 3 1 FBM Series 8 4 For ease in installation the filter box should be attached before the indoor unit is mounted 9 5 Converting the filter box from rear as supplied to bottom return 10 FBM Series Specifications are subject to change without notice 3 2019 Mitsubishi Electric US Inc ...

Page 4: ...4 ...

Page 5: ... unit if the carton is damaged If damage is found it should be noted on the carrier s freight bill Damage claims should be filed with the carrier immediately Claims of shortages should be filed with the seller within 5 days FBM Series Specifications are subject to change without notice 5 2019 Mitsubishi Electric US Inc ...

Page 6: ...ssory Incomplete installation could cause injury When you notice exceptionally abnormal noise or vibration stop operation and contact your dealer CAUTION Use proper safety equipment for the Installation work Tighten all screws as specified in the instructions Over tightening screws can cause damage to parts Not following properly installation instructions may result in air flow not passing through...

Page 7: ... When you need to dispose of the unit or filters consult your dealer to dispose in accordance with local laws and regulations FBM Series Specifications are subject to change without notice 7 2019 Mitsubishi Electric US Inc ...

Page 8: ...P12NMAU E 10 27 5 8 13 1 FBM2 2 A PEFY P15 P18NMAU E PEAD A09 A12 A15 18AA 10 35 1 2 13 1 1 FBM2 3 A PEFY P24 P27 P30NMAU E PEAD A24 30AA 10 43 3 8 13 2 FBM2 4 A PEFY P36 P48NMAU E PEAD A36 42AA 10 55 1 8 13 1 2 FBM2 5 A PEFY P54NMAU E 10 63 13 3 All models for PEFY E E2 etc for PEAD AA4 AA5 AA7 etc FBM Series 2019 Mitsubishi Electric US Inc 8 Specifications are subject to change without notice ...

Page 9: ...filter s making sure the airflow direction is correct 7 Reinstall the filter box door and mark the installation date on the label 8 The indoor unit is now ready to be mounted Use of Filte r per Mo del typ e 7 8 6 Air flow direction in filter s From Duct Flanges to Back of Filter Box Metal Spacer Screw the metal spacer here Screw the metal spacer here 5 NOTE In this view some parts were removed to ...

Page 10: ...uct flanges Inlet flow Inlet flow Bottom Return When you notice exceptionally abnormal noise or vibration stop operation and contact your dealer Warning Use proper safety equipment for the Installation work Tighten all screws as specified in the instructions Over tightening screws can cause damage to parts Not following properly installation instructions may result in air flow not passing through ...

Page 11: ...11 ...

Page 12: ... put the contact address telephone number on this manual before handing it to the customer Manufactured for MITSUBISHI ELECTRIC US INC www mitsubishielectric usa com Toll Free 800 433 4822 MEUS DOC MD 1825 K002 ver 1 September 2019 PA79C911H01 Specifications are subject to change without notice 2019 Mitsubishi Electric US Inc ...

Reviews: