6) Start at the same time both “DEGAUSS (+)” pushing and External degaussing signal generator
running.
7) Uneven color is not observed by visual check. When uneven color observes, it should be rejected.
8) Set magnetic field to “Bh=-0.03mT”.
9) Start at the same time both “DEGAUSS (+)” pushing and External degaussing signal generator
running.
10) Uneven color is not observed by visual check. When uneven color observes, it should be rejected.
11) Set magnetic field to “Bh=0.00mT”.
12) Start at the same time both “DEGAUSS (+)” pushing and External degaussing signal generator
running.
13) Uneven color is not observed by visual check. When uneven color observes, it should be rejected.
14) Using same inspection procedure as above, check Blue color.
15) Using same inspection procedure as above, check Green color.
16) After finish above inspection, connect degauss coil to MAIN BOARD S101.
Summary of Contents for Diamond Pro 930SB