![Mitsubishi Electric DD-8020 Service Manual Download Page 3](http://html.mh-extra.com/html/mitsubishi-electric/dd-8020/dd-8020_service-manual_239352003.webp)
SAFETY NOTICE
SAFETY PRECAUTIONS
LEAKAGE CURRENT CHECK
Plug the AC line cord directly into a 120V AC outlet (do
not use an isolation transformer for this check). Use an
AC voltmeter, having 5000
Ω
per volt or more sensitivity.
Connect a 1500
Ω
10 W resistor, paralleled by a 0.15
µ
F
150V AC capacitor between a known good earth ground
(water pipe, conduit, etc.) and all exposed metal parts of
cabinet (antennas, handle bracket, metal cabinet
screwheads, metal overlays, control shafts, etc.).
Measure the AC voltage across the 1500
Ω
resistor.
The test must be conducted with the AC switch on and
then repeated with the AC switch off. The AC voltage
indicated by the meter may not exceed 0.3 V. A reading
exceeding 0.3 V indicates that a dangerous potential
exists, the fault must be located and corrected.
Repeat the above test with the DVD VIDEO PLAYER
power plug reversed.
NEVER RETURN A DVD VIDEO PLAYER TO THE
CUSTOMER WITHOUT TAKING NECESSARY
CORRECTIVE ACTION.
READING SHOULD NOT EXCEED 0.3V
DVD VIDEO PLAYER
AC VOLTMETER
(5000
W
per volt
or more sensitivity)
Good earth ground
such as a water pipe,
conduit, etc.
1500
W
10 W
0.15
µ
F 150V AC
AC OUTLET
Test all exposed metal.
Voltmeter Hook-up for Leakage Current Check
Summary of Contents for DD-8020
Page 2: ... ...
Page 6: ... ...
Page 30: ...2 10 ...
Page 34: ...3 4 ...
Page 39: ...Fig 3 4 5 4 3 3 Front Display Power Switch Block Diagram 3 12 3 11 FWD REV ...
Page 41: ...Fig 3 4 7 4 4 2 Logical System Block Diagram 3 16 3 15 ...
Page 44: ...Fig 3 5 3 5 2 Front Display Power Switch Circuit Diagram 3 22 3 21 ...
Page 47: ...Fig 3 5 5 5 3 2 Main Circuit Diagram 3 25 3 26 3 27 3 28 ...
Page 48: ...5 4 Output Circuit Diagram Fig 3 5 6 3 30 3 31 3 32 3 29 ...
Page 50: ...3 34 5 5 Motor System Circuit Diagram Fig 3 5 8 ...
Page 52: ...3 36 ...
Page 60: ......
Page 67: ......
Page 68: ......