3 Controller
Dedicated input/output
3-39
3.5 Dedicated input/output
Show the main function of dedicated input/output in the
. Refer to attached instruction manual
"Detailed explanations of functions and operations" in the product for the other functions. Each parameter
indicated with the parameter name is used by designated the signal No., assigned in the order of input
signal No. and output signal No.
Table 3-2: Dedicated input/output list
Parameter
name
Input
Note1)
Output
Name
Function
Level
Name
Function
TEACHMD
None
Teaching mode
output signal
Outputs that the teaching mode is
entered.
ATTOPMD
None
Automatic mode
output signal
Outputs that the automatic mode is
entered.
ATEXTMD
None
Remote mode
output signal
Outputs that the remote mode is
entered.
RCREADY
None
Controller power
ON complete signal
Outputs that external input signals
can be received.
AUTOENA
Automatic
operation
enabled input
signal
Allows automatic operation.
L
Automatic operation
enabled output
signal
Outputs the automatic operation
enabled state.
START
Start input signal
Starts all slots.
E
Operating output
signal
Outputs that the slot is operating.
STOP
Stop input signal
Stops all slots.
The input signal No. is fixed to 0.
Note) Use the emergency stop
input for stop inputs related
to safety.
L
Wait output signal
Outputs that the slot is temporarily
stopped.
STOP2
Stop input signal
The program during operation is
stopped.
Unlike the STOP parameter,
change of the signal number is
possible.
Notes) Specification is the same
as the STOP parameter.
L
Wait output signal
Outputs that the slot is temporarily
stopped.
Notes) Specification is the same as
the STOP parameter.
SLOTINIT
Program reset
input signal
Resets the wait state.
E
Program selection
enabled output
signal
Outputs that the slot is in the
program selection enabled state.
ERRRESET Error reset input
signal
Resets the error state.
E
Error occurring
output signal
Outputs that an error has occurred.
CYCLE
Cycle stop input
signal
Carries out cycle stop.
E
In cycle stop
operation output
signal
Outputs that the cycle stop is
operating.
SRVOFF
Servo ON
enabled input
signal
Turns the servo OFF for all
mechanisms.
L
Servo ON enabled
output signal
Outputs servo-on disable status.
(Echo back)
SRVON
Servo ON input
signal
Turns the servo ON for all
mechanisms.
E
In servo ON output
signal
Outputs the servo ON state.
IOENA
Operation rights
input signal
Requests the operation rights for
the external signal control.
L
Operation rights
output signal
Outputs the operation rights valid
state for the external signal control.
MELOCK
Machine lock
input signal
Sets/resets the machine lock
state for all mechanisms.
E
In machine lock
output signal
Outputs the machine lock state.
SAFEPOS
Evasion point
return input
signal
Requests the evasion point
return operation.
E
In evasion point
return output signal
Outputs that the evasion point return
is taking place.
OUTRESET General-purpose
output signal
reset
Resets the general-purpose
output signal.
E
None
EMGERR
None
Emergency stop
output signal
Outputs that an emergency stop has
occurred.