About the communication setting (Ethernet)
5-489
5.15 About the communication setting (Ethernet)
The port number used for communication is shown in
Table 5-13: Port number to use
5.15.1 Details of parameters
(1) NETIP (IP address of robot controller)
The IP address of the robot controller is set. IP address is like the address of the mail.
The format of IP address is composed of 4 numbers of 0 to 255 and the dot (.) between the numbers.
For example, it is set as 192.168.0.1.
If the controller and network personal computer are directly connected to each other one-to-one, it is
allowed to set default value (a random value) but if it is connected to the local area network (LAN), IP
address must be set as instructed by the manager of customer's LAN system.
If any IP addresses are overlapped, the function will not properly operate. Therefore, take care to prevent it
from being overlapped with another during setting.
The personal computer used for communication with the robot controller must be located on the same net-
work.
(2) NETMSK (sub-net-mask)
Set the sub-net-mask of the robot controller. Among the IP addresses, the sub-net-mask is set to define the
sub-net-work.
The format of the sub-net-mask is composed of 4 numbers of 0 to 255 and the dot (.) between the numbers.
For example, it is set as 255.255.255.0 or 255.255.0.0.
As usual, it is allowed to set default value. If it is connected to the local area network (LAN), the sub-net-
mask must be set as instructed by the manager of customer's LAN system.
(3) NETPORT (port No.)
The port No. of the robot controller is set. The port No. is like the name of the mail.
For the nine elements, the port numbers are each expressed with a value.
The first element (element No. 1) is used for real-time control.
The second to ninth elements (elements No. 2 to 9) are used for the support software or data link.
Normally, the default value does not need to be changed. Make sure that the port numbers are not dupli-
cated.
Port number
Application
Parameter
Note1)
Note1) With a few exceptions, the port number can be changed by parameter. The setting range is 0 to 65535.
20
Reserved
21
Reserved
23
COGNEX vision sensor
Cannot be changed
111
Reserved
502
Reserved
1024
Reserved
5001
GOT communication
GOTPORT
10000
Mxt command
NETPORT
10001
RT ToolBox2 (This port can also be used for Data link)
NETPORT
10002 to 10009
Data link (This port can also be used for RT ToolBox2)
NETPORT
11000
R56TB/R57TB
Cannot be changed (TBPORT)
12000
Oscillograph function
MONPORT
43815
Reserved
43816
Reserved