background image

Module :

 

PUHY-P96TKMU-A – DIMENSIONS

(7/8)

(1-3/4)

(1-3/8)

(2-15/32)

(1-1

1/32)

(2-1/16)

(2-9/16)

(3-23/32)

(5-29/32)

(5-17/32)

(3-1/16)

(1/2)

(3/8)

(7/8)

(1-1/8)

(3/8)

Note1.Please refer to the next page for information            regarding necessary spacing around the            unit and foundation work.         2.At brazing of pipes, wrap the refrigerant service valve             with wet cloth and keep the temperature of             refrigerant service valve under 120°C(248

°F).

Gas

Liquid

Refrigerant pipe

Liquid

Diameter

Model

Service valve

Connecting pipe specifications

Gas

(ø12.7 Brazed)

ø9.52 Brazed

ø22.2 Brazed

ø28.58

ø9.52

PUHY

-P96TKMU

3

4

7

(1-3/16)

(1-3/16)

(Mounting pitch)

(26-23/32~26-15/16)

(26-13/16)

(Mounting pitch)

(3-5/32)

(3-5/32)

Refrigerant service  valve <gas>

Refrigerant service valve <liquid>

(4-25/32)

(8-9/16)

(5-3/4) 
(7-23/32)

(5-23/32)

(3-5/16)

(3-23/32)

(10-23/32)

(1

1-7/8)

(8-15/16)

(8-3/4)

(6-25/32)

(2-1/4)

(2-1/4)

(13/16)

(13/16)

(3-17/32)

(3-1/16)

1

(9-29/32)

(10-23/32)

(11-15/16)

(25/32)

(25/32)

(2-25/32)

=(5-29/32)X4

(23-5/8)

<Snow hood attachment hole>

4X5-ø4.6(3/16) Hole (Make hole at the plastic fan guard  for snow hood attachment)

Intake air

Discharge air

Refrigerant service valve  <gas>

Refrigerant service valve  <liquid>

Control box

Intake air

Service panel

Intake air

<Sling hole>

2

5

2X2-14(9/16)X20(13/16) Oval hole

2X2-80(3-5/32)X35(1-13/32) Oval hole

6

ø34 Knockout hole

ø52 Knockout hole

ø65 Knockout hole

ø43.7 or ø22.2 Knockout hole

ø62.7 or ø34.5 Knockout hole

150 × 94 Knockout hole

140 × 77 Knockout hole

Specifications

For transmission cables

For pipes

Bottom through hole

Front through hole

Usage

For wires

Front through hole

Front through hole

Bottom through hole

Bottom through hole

Front through hole

NO.

*1

*2 *3

*2

*1 Expand the on-site piping and connect to the refrigerant service valve piping. *2 Use the pipe joint(field supply) and connect to the refrigerant service valve piping.

*3 Furthest piping length (OU from IU)   90m(295ft)

217

Bottom view

Left side view

Front view

Top view

145

222

(740)(29-5/32)

150(5-29/32)

83(3-9/32)

272

301

57

29.5

54(2-5/32)

19.5

58(2-5/16)

80

1060(41-3/4)

586(23-3/32)

19.5

57

94

84

121

227

600=150×4

20

75(2-31/32)

1220(48-1/16)

172

150(5-29/32)

1650(64-31/32)

196

272

1347(53-1/16)

89

303

29.5

20

740(29-5/32)

70

1181(46-1/2)

140(5-17/32)

80

77

146

251

681(678~684)

> =

Unit : mm(in.)

PUHY-P96TKMU-A(-BS)

1

2

3

4

5

6

7

Summary of Contents for City Multi PUHY-P120TKMU-A

Page 1: ...stem Data Heating Power Input kW 19 26 Cooling Current 208 230V R L A 52 1 47 1 Refer to System Data Heating Current 208 230V R L A 59 4 53 7 Minimum Circuit Ampacity MCA A Refer to Module Data 45 42 34 31 Maximum Breaker Size A Refer to Module Data 50 40 Maximum Overcurrent Protection A Refer to Module Data 73 67 57 52 Piping Diameter Refer to System Data From Twinning Kit to Indoor Units Brazed ...

Page 2: ...anual for details of Twinning pipe installation 3 The pipe section before the Twinning pipe sections a and b in the figure must have at least 500mm 19 11 16 of straight section including the straight pipe that is supplied with the Twinning pipe 4 Only use the Twinning pipe by Mitsubishi optional parts d or f c or e Gas Liquid P96 P120 Unit model Twinning pipe Outdoor unit Front view Left view To i...

Page 3: ...ic fan guard for snow hood attachment Snow hood attachment hole Refrigerant service valve gas Refrigerant service valve liquid 6 25 32 8 25 32 ø34 Knockout hole ø52 Knockout hole ø65 Knockout hole ø43 7 or ø22 2 Knockout hole ø62 7 or ø34 5 Knockout hole 150 94 Knockout hole 140 77 Knockout hole Specifications For transmission cables For pipes Bottom through hole Front through hole Usage For wires...

Page 4: ...ttachment Intake air Discharge air Refrigerant service valve gas Refrigerant service valve liquid Control box Intake air Service panel Intake air Sling hole 2 5 2X2 14 9 16 X20 13 16 Oval hole 2X2 80 3 5 32 X35 1 13 32 Oval hole 6 ø34 Knockout hole ø52 Knockout hole ø65 Knockout hole ø43 7 or ø22 2 Knockout hole ø62 7 or ø34 5 Knockout hole 150 94 Knockout hole 140 77 Knockout hole Specifications ...

Page 5: ...ronmental protection set by the International Standard Organization ISO Twinning Kit CMY Y100CBK3 1 15 16 2 pcs 2 pcs 3 7 8 9 1 2 7 7 32 3 9 32 19 29 32 13 15 32 23 5 32 6 5 16 2 15 32 1 15 16 2 15 32 Distributer Distributer Pipe cover Dot dashed part 1 2 1 2 1 2 1 2 Local brazing Note 2 5 8 5 8 1 1 8 Note 2 1 7 8 1 7 8 Pipe cover Dot dashed part Local brazing 1 1 8 2 pcs 7 8 3 4 1 2 5 8 1 2 3 8 1...

Reviews: