16
1
2
3
4
5
6
7
8
9
10
1~6
1
2
3
4
5
6
7
8
1~4
Thermistor<Intake temperature
detection>position
ON
OFF
Filter clogging detection
Provided
Not provided
Filter life
2,500hr
100hr
Air intake
Effective
Not effective
Remote indication switching
Thermostat ON signal indication Fan output indication
Humidifier control
Always operated while the heat is ON
Operated depends on the condition
Air flow st
Low
Extra low
Heat thermostat OFF
Setting air flow
Reset to SW1-7
Auto reset function
Effective
Not effective
Power ON/OFF
Effective
Not effective
Heat pump/Cool only
Cooling only
Heat pump
Louver
Available
Not available
Vane
Available
Not available
Vane swing function
Available
Not available
Vane holizontal angle
Second setting
First setting
Vane cooling limit angle setting
Horizontal angle
Down blow
Heating 4deg up
Not effective
Effective
ON
OFF
1 2 3 4 5 6 7 8 9 10
ON
OFF
1 2 3 4 5 6 7 8 9 10
ON
OFF
1 2 3 4 5 6
ON
OFF
1 2 3 4 5 6
MODELS
SW2
MODELS
SW2
MODELS
SW2
PFFY-
P06NEMU-E
PFFY-
P15NEMU-E
PFFY-
P08NEMU-E
PFFY -
P18NRMU-E
Address board
<At delivery>
Indoor controller board
Indoor controller board
Indoor controller board
<At delivery>
<At delivery>
SW4
Unit
Selection
SW3
Function
Selection
SW2
Capacity
code
setting
SW1
Mode
Selection
Switch Pole
Function
Built-in remote controller
Indoor unit
Set while the unit is off.
<At delivery>
Set for each capacity.
Set while the unit is off.
(Note:1) At cooling mode, each
angle can be used
only 1 hour.
Set while the unit is off.
Operation by switch
Remarks
ON
OFF
1 2 3 4 5 6
PFFY -
P12NEMU-E
PFFY-
P15NRMU-E
PFFY-
P08NRMU-E
ON
OFF
1 2 3 4 5 6
ON
OFF
1 2 3 4 5 6
ON
OFF
1 2 3 4 5 6
PFFY-
P06NRMU-E
PFFY-
P18NEMU-E
ON
OFF
1 2 3 4 5 6
ON
OFF
1 2 3 4 5 6
ON
OFF
1 2 3 4 5 6
PFFY -
P24NEMU-E
PFFY-
P12NRMU-E
PFFY-
P24NRMU-E
ON
OFF
1 2 3 4 5 6
ON
OFF
1 2 3 4 5 6
ON
OFF
1 2 3 4 5 6
ON
OFF
1 2 3
5
4
Note
DipSW setting is effective during unit stopping ( remote controller OFF ) for SW1,2,3 and 4 commonly and the
power source is not required to reset.
1:The
220V
240V
220V
240V
Address board
<At delivery>
2
SW5
Voltage
Selection
If the unit is used at the 230V or 240V area,
set the voltage to 240V.
If the unit is used at the 220V, set the voltage
to 220V.
Note:2
2:The DipSW setting is effective during unit stopping ( remote controller OFF ) for SW11,12,14 and 5.
7-3. Function of Dip-switch
7-4. Function
the
Symbol
Silk display
LED operation under normal state
Lighting
LED1
Main power source
At applying main power source
At receiving M-NET transmission power source
LED2
Transmission power source
Lighting
7-4. Function the
unit
of the indoor
LED
service board