background image

4

6.2

[Fig. 6.2.1]

[Fig. 6.2.2]

7

[Fig. 7.0.1]

[Fig. 7.0.2]

8

8.1

[Fig. 8.1.1]

C

C

C

D

B

A

A

Downward slope 1/100 or more

B

Drain hose (Accessory)

C

Indoor unit

D

Collective piping

C

D

G

F

E

B

5

25

A

A

Indoor unit

B

Tie band (accessory)

C

Band fixing part

D

Insertion margin

E

Drain hose (accessory)

F

Drain pipe (O.D. ø32 PVC TUBE, field supply)

G

Insulating material (field supply)

(Unit: mm)

B

D

F

A

G

C

E

A

Air inlet

B

Air filter

C

Duct

D

Canvas duct

E

Access door

F

Wall

G

Air outlet

B

A

C

A

Filter

B

Front plate

C

Fan guard

A   B

C

C

C

C

D

C

~ 220 -240V

A

Ground-fault interrupter

B

Local switch/Wiring breaker

C

Indoor unit

D

Pull box

VZ79D813H01_DA.book  4 ページ  2018年12月3日 月曜日 午後5時17分

Summary of Contents for CITY MULTI PFFY-P20VCM-E

Page 1: ...oken noga innan luftkonditioneringsenheten installeras för säker och korrekt användning pl no ru bg РЪКОВОДСТВО ЗА МОНТАЖ За безопасна и правилна употреба моля прочетете внимателно това ръководство преди монтажа на климатизатора PODRĘCZNIK INSTALACJI W celu bezpiecznego i poprawnego korzystania należy przed zainstalowaniem klimatyzatora dokładnie zapoznać się z niniejszym podręcznikiem instalacji ...

Page 2: ...the wall Viewed from front of the unit A Floor Unit mm A B B C A A Nuts field supply B Washers C M10 Hanging bolt field supply For PFFY P VCM E mm Model name A B 20 25 32 700 More than 240 40 50 900 More than 240 63 1100 More than 240 A Floor B Piping space C Electrical part service space For PFFY P VCM E mm Model name E F 20 25 32 730 756 40 50 930 956 63 1130 1156 VZ79D813H01_DA book 2 ページ 2018年...

Page 3: ...nt piping liquid B Refrigerant piping gas C Drain outlet Unit mm B A A Cut here B Remove brazed cap A A Cool by a wet cloth A A E C F B D A Thermal insulation B Pull out insulation C Wrap with damp cloth D Return to original position E Ensure that there is no gap here F Wrap with insulating tape VZ79D813H01_DA book 3 ページ 2018年12月3日 月曜日 午後5時17分 ...

Page 4: ...xing part D Insertion margin E Drain hose accessory F Drain pipe O D ø32 PVC TUBE field supply G Insulating material field supply Unit mm B D F A G C E A Air inlet B Air filter C Duct D Canvas duct E Access door F Wall G Air outlet B A C A Filter B Front plate C Fan guard A B C C C C D C 220 240V A Ground fault interrupter B Local switch Wiring breaker C Indoor unit D Pull box VZ79D813H01_DA book ...

Page 5: ...rew holding cover 3pcs B Cover C B A A Terminal bed box B Knockout hole C Remove C H J I D N L N L M1 1 2 M2 S B E A G F A Use a cable tie to secure the cable B Use PG bushing to keep the weight of the cable and external force from being applied to the power supply terminal connector C Power source wiring D Use ordinary bushing E Power source terminal block F Terminal block for indoor transmission...

Page 6: ...6 8 6 Fig 8 6 1 SW21 SW14 SW12 SW11 Indoor controller board VZ79D813H01_DA book 6 ページ 2018年12月3日 月曜日 午後5時17分 ...

Page 7: ... away from water washing water etc It might result in electric shock catching fire or smoke Securely install the outdoor unit terminal cover panel If the terminal cover panel is not installed properly dust or water may enter the outdoor unit and fire or electric shock may result Do not use refrigerant other than the type indicated in the manuals pro vided with the unit and on the nameplate Doing s...

Page 8: ... circuit breaker is not installed electric shock may result Use power line cables of sufficient current carrying capacity and rating Cables that are too small may leak generate heat and cause a fire Use only a circuit breaker and fuse of the specified capacity A fuse or circuit breaker of a larger capacity or a steel or copper wire may result in a general unit failure or fire Do not wash the air c...

Page 9: ... the unit at level using a level Caution Install the unit in horizontal position If the side with drain port is installed higher water leakage may be caused 5 Refrigerant pipe and drain pipe specifications To avoid dew drops provide sufficient antisweating and insulating work to the refrig erant and drain pipes When using commercially available refrigerant pipes be sure to wind commercially availa...

Page 10: ...on indoors and keep both ends of the piping sealed until just before brazing If dust dirt or water gets into the refrigerant cycle the oil will deteriorate and the compressor may fail Use Suniso 4GS or 3GS small amount refrigerator oil to coat the flare and flange connection part For models using R22 Use ester oil ether oil or alkylbenzene small amount as the refrigerator oil to coat flares and fl...

Page 11: ... shall be provided by the Air conditioner installation Fig 8 1 1 P 4 Apply to IEC61000 3 3 about Max Permissive System Impedance 1 The Ground fault interrupter should support Inverter circuit The Ground fault interrupter should combine using of local switch or wiring breaker 2 Please take the larger of F1 or F2 as the value for F0 F1 Total operating maximum current of the indoor units 1 2 F2 V1 Qu...

Page 12: ...roller Fig 8 2 4 P 5 M NET Remote controller The MA remote controller and the M NET remote controller cannot be used at the same time or interchangeably Caution Install wiring so that it is not tight and under tension Wiring under tension may break or overheat and burn 8 3 Connecting electrical connections Please identify the model name of the operation manual attached on the terminal box cover wi...

Page 13: ...t addresses and branch numbers at will The determination of indoor unit addresses varies with the system at site Set them referring to the Data Book 8 7 Sensing room temperature with the built in sen sor in a remote controller If you want to sense room temperature with the built in sensor in a remote controller set SW1 1 on the control board to ON The setting of SW1 7 and SW1 8 as nec essary also ...

Page 14: ...14 en VG79D813H01_en book 14 ページ 2018年12月14日 金曜日 午前11時20分 ...

Page 15: ...IP20 N 10 R410A 4 15 220 220 230 230 240 240 VZ79D813H01_DA book 171 ページ 2018年12月3日 月曜日 午後5時17分 ...

Page 16: ...wing EU regulations Low Voltage Directive 2014 35 EU Electromagnetic Compatibility Directive 2014 30 EU Machinery Directive 2006 42 EC Please be sure to put the contact address telephone number on this manual before handing it to the customer HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN VG79D813H01_en book 172 ページ 2018年12月14日 金曜日 午前11時20分 ...

Reviews: