Number of SIO output ON times integration function
This function counts the number of SIO output ON times of each channel. (Range: 0 to 65535)
Description
This function holds the integration value even if the IO-Link device is replaced, but it clears the integration value if the IO-Link
module is powered off.
The integration value is reset to 0 to restart counting when it exceeds 65535.
■
Reading the integration value
The integration value can be read from the parameter setting window of the engineering tool or the program.
For details on reading the integration value via a program, refer to the following.
■
Resetting the integration value
The integration value can be reset by writing 0 from the parameter setting window of the engineering tool or the program.
Setting procedure
1.
Open the "CC IE Field Configuration" window.
For the master/local module RJ71GF11-T2
[Navigation window]
[Parameter]
[Module Information]
[RJ71GF11-T2]
[Module Parameter]
[Basic Settings]
[Network Configuration Settings]
2.
Open the "Parameter Processing of Slave Station" window.
From the list of stations, select an IO-Link module
[CC IE Field Configuration]
[Online]
[Parameter Processing of
Slave Station].
3.
Set "Method selection" to "Parameter Write".
4.
Set "Write Value" of "Number of ON times setting".
Precautions
When the ON time and the OFF time of the output signal are less than 10ms, the IO-Link module cannot recognize the output
change and the number of ON times may not be counted.
Item
Setting range
Number of ON times Y0 to
Number of ON times YF
0 to 65535
Summary of Contents for CC-Link IE Field NZ2GF12A-60IOLH8
Page 1: ...CC Link IE Field Network Waterproof Remote IO Link Module User s Manual NZ2GF12A 60IOLH8 ...
Page 2: ......
Page 30: ...28 3 PROCEDURES BEFORE OPERATION MEMO ...
Page 100: ...98 8 MODULE FUNCTION BLOCKS MEMO ...
Page 109: ...9 PROGRAMMING 9 2 Program Example of Setting Parameters Using a Dedicated Instruction 107 9 ...
Page 116: ...114 9 PROGRAMMING 9 3 Example of Program to Communicate with an IO Link Device ...
Page 118: ...116 10 MAINTENANCE AND INSPECTION MEMO ...
Page 155: ...APPX Appendix 7 Additional or Changed Functions 153 A MEMO ...
Page 157: ...I 155 MEMO ...
Page 161: ......